English
Language : 

HM1500LF Datasheet, PDF (1/3 Pages) Humirel – RELATIVE HUMIDITY MODULE
RELATIVE HUMIDITY MODULE
HM1500LF
Compliant with RoHS recommendations
Based on the rugged HS1101LF capacitive humidity sensor, HM1500LF is a dedicated humidity transducer
designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a
micro-controller is made possible with the module’s linear voltage output.
MAIN FEATURES
Small size.
Product free from Lead, Cr(6+), Cd and Hg.
Not affected by water immersion.
Full interchangeability.
High reliability and long term stability.
Typical 1 to 3.6 Volts DC output for 0 to 100 % RH at 5 V DC supply.
Calibrated within +/- 2 % RH @ 55 % RH.
Very low temperature dependence.
Ratiometric to voltage supply from 4.75Vdc to 5Vdc.
Able to operate from 3 to 10 Volts supply voltage
HUMIDITY SENSOR SPECIFIC FEATURES
Instantaneous de-saturation after long periods in saturation phase.
Fast response time.
Not affected by water immersion.
Part could be washed with distilled water.
Patented solid polymer structure.
MAXIMUM RATINGS
Ratings
Symbol
Value
Unit
Storage Temperature
Storage Humidity Range
Supply Voltage (Peak)
Tstg
RHstg
Vs
-30 to 70
0 to 100
10
°C
% RH
Vdc
Humidity Operating Range
RH
0 to 100 % RH
Temperature Operating Range Ta
-40 to 60
°C
CHARACTERISTICS
(Ta =23°C, Vs=5.0Vdc, RL >1MΩ unless otherwise stated)
Characteristics
Symbol Min
Humidity Measuring Range
RH
0
Relative Humidity Accuracy (10% to 95%RH)
Voltage Supply(regulated at 5Vdc)
Vcc
Nominal Output @55%RH (Vs=5Vdc)
Current Consumption
Vout
2.42
Icc
Temperature coefficient (10 to 50°C)
Humidity Average Sensitivity
Tcc
∆mV/RH
Response time ( at 63% of signal) 33%RH to
τ
75%RH
Humidity hysteresis
Output impedance
Z
Sink current capability (RL = 33 kOhms)
I
Warm up time(electronic)
tw
Humidity Resolution
HPC062 Rev B April 2005
TECHNICAL 1 DATA
Typ
±3
5
2.48
2.8
-0.05
+26
70
150
0.4
Max
100
±5
2.54
4
-0.1
10
Unit
%RH
%RH
Vdc
V
mA
%RH/°C
mV/%RH
s
+/-1
%RH
Ω
150
µA
ms
%RH
HM1500LF