9 Mechanical Characteristics机构特性 :
试验项目
试验方法
结果
Test Item
Test Method
Result
拉力强度(依据 JIS C0051) 施加 2.5Kgf 之荷重于导线约 30 秒钟后,检测直流开始放电电压, 满足各个特性之规格值
Pull Strength (JIS C0051) 绝缘阻抗,靜电容量及检查外观. (Apply 2.5 kgs load
Within standard
approximately 30 seconds, then check for pull-out and breaking mentioned in Initial
of the lead wire.)
Characteristics.
弯曲強度 (依据 JIS C0051) 距离导线熔接点根部 3mm 处,使用曲率半径 0.75~0.80mm 之治 满足各个特性之规格值
Flexure Strength(JIS
具,与轴方向垂直角度,荷 0.25Kgf 弯曲后回复原状,反复 2 次后,
Within standard
C0051)
检测直流开始放电电压,绝缘阻抗,靜电容量及检查外观.(Bend
mentioned in Initial
the lead wire, with jig which radius is 0.75~0.8mm, at the point
Characteristics.
of 3mm from the body, under 0.25 kgs load applied at the right
angle the direction of the amis and get the bent lead wire back
to its original poing after the procedure was repeated 2 times.)
10 Solder Characteristics 焊锡特性 :
试验项目
试验方法
结果
Test Item
Test Method
Result
焊锡附着性
将沾过助焊剂之导线,自距离导线熔接点根部 3mm 处起,浸于
導線須均勻附著 90%上.
(依据 JIS C0050 4.6 项) 265±5℃之焊锡液中 5 秒钟后,将导线之助焊剂洗净后,检查焊锡附 (Lead wire is evenly
Solderability (JIS 着情形.(Apply flux and immerse in molten solder, up to the point
covered by solder over
C0050,4.6)
of 3mm from the body,for 5 sec. (265℃±5℃). Wash the leadwire and 90%.)
check for soldering adhesion.)
焊锡耐热性
将沾过助焊剂之导线,自距离导线熔接点根部 2mm 处起,浸于
满足各個特性之规格值
(依据 JISC0051)
265±5℃之焊锡液中 10 秒钟后,检测直流开始放电电压,绝缘阻抗,靜电
Within standard
Solder Heat
容量及检查外观. (Lead wire is dipped up to the point of
mentioned in Initial
(JIS C0051)
2mm from the body, into 265℃±5℃ solder.for 10±1 sec.And
Characteristics.
measure the properties.)
11 Surge Characteristics 突波特性 :
试验项目
试验方法
结果
Test Item
Test Method
Result
突波寿命(HA41) 将(10X700)μsec-1KV 突波,变换极向各 5 次,(100X1000)μsec-1KV 之突波,变换极向各 6 直流开始放电电压 HA41
Life(HA41)
次,每隔 30 秒施加于试料 24 次后,检测直流开始放电电压,绝缘阻抗,靜电容量及检查外观 △Vs/Vs≦30% (DC sparkover
(Apply a standard impulse voltage (10X700)μsec)of 1KV for 5 times with intervals of 30 volatage HA41:
sec., and then change the polarity of the surge and apply a impulse again. And similarly, △Vs/Vs≦30%)
apply a impulse voltage((100X1000)μsec) of 1KV. Total apply 24 times. Then measure
DC spark-over voltage, IR & Capacitance.)
突波寿命(HA41) 每间隔 10 秒施加 10KV 之电压于 1500PF 之电容器通过试料,做 200 次(Apply 10 KV
绝缘阻抗和静电电容:须满足规
Life(HA41)
voltage charged in 1500pF condenser and apply the current to the specimen,200 times 定值 外观:无影响使用之显著缺
at 10 seconds of intervals.)
陷 (Insulation Resistance &
Capacitance to meet the
specified value.Appearance:
No cracks or failures .)
4
HUAAN LIMITED
www.huaandz.com