English
Language : 

NX2SA Datasheet, PDF (1/2 Pages) HuaXinAn Electronics CO.,LTD – DIL pitch terminals .Surface mount type with L shaped teminal;
NX
15.0 7.5 9.4
R
C
US E169380
Features
DIL pitch terminals .Surface mount type with L shaped teminal;
Conforms to FCC Part 68 2.5kV Surge and Dielectric 1500VAC;
High contact capacity 2A/30VDC;
Application for Telecommunication Equipment,Office Equipment, Security Alarm Systems, Measuring instruments,
Medical Monitoring Equipment,Audio Visual Equipment, Flight Simulator,Sensor Control.
Ordering Information
NX 2 SA L H 12 W
1 2 3 4567
1 Part number NX
2 Contact arrangement 2:2C
3 Mount NIL:DIL SA: Standard SMT
SL: High connection reliability SMT
4 Operating function Nil: Single Side Stable
L:1 Coil Latching
5 Terminal NIL: Standard DIL or SMT H:Self-clinching terminal
6 Coil rated Voltage(V) DC:3,4.5,5,6,9,12,24
7 Contact Material NIL:AgPd W:AgNi
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
2C DPDT(B-M)
AgPd( Gold clad ) AgNi( Gold clad )
2A/30VDC 0.5A/125VAC
60W, 62.5VA
Min. Switching load 0.01mA/10mV
220VDC, 250VAC
Max. Switching Current:2A
Reference Value
Contact Resistance or
Voltage drop
70m (80 m SMT)
Item 4.12 of IEC 61810-7
Operational
life
Electrical
Mechanical
1A/30VDC 5 105
2A/30VDC 1 105
108
Item 4.30 of IEC 61810-7
Item 4.31 of IEC 61810-7
CAUTION:
Relays previously tested or used above 10mA resistive at 6V maximum DC or peak AC open circuit are not
recommended for subsequent use in low level applications.
Coil Parameter
Dash
numbers
Coil voltage
VDC
Rated Max.
Coil resistance
10%
Pick up voltage
VDC(max)
(75%of rated
voltage )
Release voltage
VDC(min)
(10% of rated
voltage)
Coil
power
W
Operate
Time
ms
Release
/Reset
Time
ms
NX2-003
3
NX2-004 4.5
NX2-005
5
NX2-006
6
NX2-009
9
NX2-012 12
NX2-024 24
1 Coil Latching
4.5
6.7
7.5
9.0
13.5
18.0
36.0
64.3
145
178
257
579
1028
2880
2.25
3.38
3.75
4.50
6.75
9.00
18.0
0.3
0.45
0.5
0.6
0.9
1.2
2.4
Reset(Max)
0.14
0.14
0.14
0.14
0.14
0.14
0.20
4
4
Reset
NX2L-003 3
NX2L-004 4.5
NX2L-005 5
NX2L-006 6
NX2L-009 9
NX2L-012 12
NX2L-024A 24
4.5
6.7
7.5
9.0
13.5
18.0
36.0
90
202.5
250
360
810
1440
3840
2.25
3.38
3.75
4.50
6.75
9.00
18.0
-2.25
0.10
-3.38
0.10
-3.75
0.10
-4.50
0.10
4
4
-6.75
0.10
-9.00
0.10
-18.0
0.15
35
NX
Coil Parameter
Dash
Numbers
Coil voltage
VDC
Rated Max.
NX2SA-003
3
NX2SA-004
4.5
NX2SA-005
5
NX2SA-006
6
NX2SA-009
9
NX2SA-012
12
NX2SA-024
24
1 Coil Latching
NX2SAL-003
3
NX2SAL-004 4.5
NX2SAL-005
5
NX2SAL-006
6
NX2SAL-009
9
NX2SAL-012
12
NX2SAL-024A 24
4.5
6.7
7.5
9.0
13.5
18.0
36.0
4.5
6.7
7.5
9.0
13.5
18.0
36.0
Coil
resistance
10%
64.3
145
178
257
579
1028
2880
90
202.5
250
360
810
1440
3840
Pick up voltage
VDC(max)
(75%of rated
voltage )
Release voltage
VDC(min)
(10% of rated
voltage)
Coil
power
W
Operate
Time
ms
2.25
3.38
3.75
4.50
6.75
9.00
18.0
0.3
0.45
0.5
0.6
0.9
1.2
2.4
0.14
0.14
0.14
4
0.14
0.14
0.14
0.20
Release
/Reset
Time
ms
4
Reset(Max)
Reset
2.25
3.38
3.75
4.50
6.75
9.00
18.0
-2.25
0.10
-3.38
0.10
-3.75
0.10
-4.50
0.10
4
4
-6.75
0.10
-9.00
0.10
-18.0
0.15
NX2SL-003
NX2SL-004
NX2SL-005
NX2SL-006
NX2SL-009
NX2SL-012
NX2SL-024
3
4.5
4.5
6.7
5
7.5
6
9.0
9
13.5
12 18.0
24 36.0
1Coil Latching
NX2SLL-003
3
NX2SLL-004
4.5
NX2SLL-005
5
NX2SLL-006
6
NX2SLL-009
9
NX2SLL-012
12
NX2SLL-024A 24
4.5
6.7
7.5
9.0
13.5
18.0
36.0
64.3
145
178
257
579
1028
2880
90
202.5
250
360
810
1440
3840
2.25
3.38
3.75
4.50
6.75
9.00
18.0
2.25
3.38
3.75
4.50
6.75
9.00
18.0
0.3
0.14
0.45
0.14
0.5
0.14
0.6
0.14
0.9
0.14
1.2
0.14
2.4
0.20
Reset(Max)
-2.25
0.10
-3.38
0.10
-3.75
0.10
-4.50
0.10
-6.75
0.10
-9.00
0.10
-18.0
0.15
4
4
Reset
4
4
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design criteria.
3.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously.
Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three
times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to be
in the magnetically neutral position .
4.Unless otherwise stated, the rated coil voltage specified in coil parameter and its suitable polarity(if applicable)
shall be used for all tests and its application to the relay.
5.Soldering and mountion recommendations for NX as same as P series.
Ningbo Huaguan Electronics Corporation LTD.
36