English
Language : 

NT90TP-C Datasheet, PDF (1/2 Pages) HuaXinAn Electronics CO.,LTD – Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications
NT90TP (T92)
NT90TP (T92)
32.4(50) 27 20
32.4(50) 27 28.2
03001003503
R
C
US E174722
R50126373
Features
Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration,
high reliability, long life.
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications.
Ordering Information
N90TP
1
H L A S DC12V C B 0.9
2
3 45
6
78
9
1 Part number NT90TP T92 NT90TP2
2 Load H:30A N:40A
3 High NIL: Standard L: Low profile type
4 Contact arrangement A:1A B:1B C:1C
5 Enclosure S: Sealed type D: Dust cover
E: Covered
6 Coil rated Voltage(V) AC:12,24, 110,120,220
DC:3,5,6,9,12,15,18,24,48,110
7 Contact material C: AgCdO S: AgSnO2
8 Resist heat class B:130 F:155
9 Coil power consumption 0.6:0.6W 0.9:0.9W
NIL:2VA
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation Electrical
life
Mechanical
Coil Parameter
AC Coil Parameter
1A SPSTNO 1B SPSTNC 1C SPDT(B-M)
AgCdO AgSnO2
NO:30A/240VAC,14VDC; NC:20A/240VAC;30A/14VDC
NO:40A/240VAC,30VDC; NC:30A/240VAC,30VDC (0.9W)
NO:30A/277VAC;NC:20A/277VAC
Motor load 2HP 250VAC 1.5HP 250V
Lamp load TV-5
1100W 7200VA
110VDC 300VAC
30m
105
107
Max. Switching Current:40A
Item 4.12 of IEC 61810-7
Item 4.30 of IEC 61810-7
Item 4.31 of IEC 61810-7
Dash
numbers
Rated voltage
VAC
Rated
Max
Rated
current
mA
Coil
resistance
10%
Pick up
voltage
VAC(max)
(75%of
rated
voltage)
Release
voltage
VAC(min)
(30%of
rated
voltage)
Coil
power
Operate Release
Time
Time
ms
ms
012AC
12
024AC
24
110AC
110
120AC
120
220AC
220
15.6
187
27
31.2
95
120
143
20
2360
156
16.5
3040
286
6.4
13490
9.0
18.0
82.5
90.0
165.0
3.6
7.2
33.0
2VA
36.0
66.0
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Ningbo Huaguan Electronics Corporation LTD.
118