English
Language : 

NPA Datasheet, PDF (1/1 Pages) DB Lectro Inc – Low coil power consumption 0.12W. / PC board mounting, SIL terminal
NPA
VDE 40008356
20.3 5.4 12.6
R
C
US E169380
Features
Small size, light weight.
Low coil power consumption 0.12W.
PC board mounting, SIL terminal
Suitable for household electrical appliances, automation system, electronic equipment, instrument, meter,
telecommunication facilities and remote control facilities.
Ordering Information
NPA A S 5 DC12V
1
234
5
1 Part number NPA ;NPA2
2 Contact arrangement:A:1A
3 Enclosure S:Sealed type NIL:Dust cover
4 Contact current 3:3A 5:5A
5 Coil rated voltage (V) DC:5,6,9,12,18,24
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance & Voltage drop
Operational Electrical
life
Mechanical
1A (SPSTNO)
Silver Alloy (Gold clad)
3A,5A/30VDC,250VAC;
150W 1250VAC
min Load:0.1mA/0.1VDC (reference value)
110VDC 250VAC
Max.Switching Current:5A
30m (at 1A/6V)
Item 4.12 of IEC 61810-7
1 105 5 104 (5A)
Item 4.30 of IEC 61810-7
2 107
Item 4.31 of IEC 61810-7
CAUTION:
Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not
recommended for subsequent use in low level applications.
Coil Parameter
Dash
numbers
Coil voltage
VDC
Rated Max.
Rated
current
mA
Pickup
Coil
voltage
resistance VDC (max)
10% (70%of rated
voltage )
Release
voltage
VDC (min)
(5% of rated
voltage)
Coil power Operate Release
consumption Time Time
W
ms
ms
NPA-005
5
NPA-006
6
NPA-009
9
NPA-012 12
NPA-018 18
6
7.2
10.8
14.4
21.6
24
20
13.3
10
6.7
208
300
675
1200
2700
3.5
4.2
6.3
8.4
12.6
0.25
0.3
0.45
0.6
0.9
0.12
10
5
NPA-024 24
28.8
5
3200
16.8
1.2
0.18
10
5
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
55
NPA
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
Safety approvals
Safety approval
Load
1000M min (at 500VDC)
50Hz 1000V
50Hz 2000V Surge voltage:4kV
Functional:147m/s2 11ms
Survival:980m/s2 6ms
10~55Hz Functional double amplitude 2.5mm
Survival:double amplitude 3.5mm
5N
235 2 3 0.5s
-40~85
5%~85% (at 40 )
3g
U L & CUR
3A.5A/250VAC,30VDC.
Item 7 of IEC 61810-5
Item 6 of IEC 61810-5
Item 6 and 8 of IEC 61810-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
VDE
3A.5A/250VAC,30VDC
Dimensions
20.3 max.
0.799 max.
5.4 max.
0.213 max.
NPA
2-0.5 0.3
0.020 0.012
2.54
0.1
10.16
0.300
1.1
0.046
2-0.8 0.3
0.031 0.012
5.08
0.200
20.3max.
0.787max.
1.1
0.046
0.25
0.010
5.4max.
0.213max.
NPA2
2-0.5 0.3
0.020 0.012
2.54
0.1
7.62 7.62
0.300 0.300
1.1
0.046
2-0.8 0.3
0.031 0.012
Dimensions
1.1
0.046
0.25
0.010
mm /inch
2.54
0.1
2- 1.1
0.046
2- 1.2
0.047
2.54
0.1
2- 1.1
0.046
2- 1.2
0.047
Mounting (Bottom view)
Wiring diagram
(Bottom view)
NOTES 1) Dimensions are in millimeters.
2) Inch equivalents are given for general information only.
3) If not only one relay is used at the same place, the clearance between any two items may not is less than 1mm.
Ningbo Huaguan Electronics Corporation LTD.
56