English
Language : 

NE720B Datasheet, PDF (1/1 Pages) HuaXinAn Electronics CO.,LTD – Magnet latching relay
NE720
60 40 22
Features
Magnet latching relay.
High sensitivity & reliability.
Well anti-shock and anti-vibration.
Heavy contact load.
03001003498
Ordering Information
NE720 A Z DC12V D
1
23
4
5
1 Part number NE720
2 Contact arrangement A:1A B:1B
3 Enclosure Z: Dust cover
4 Coil rated voltage(V) DC:6,12, 24
5 Coil:NIL:singal coil ;D:double coils
Contact Data
Contact Arrangement
Contact Material
Contact Rating(resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation life
Electrical
(Rated load)
Mechanical
(No load)
Coil Parameter
Dash
numbers
Coil
rated
voltage
VDC
Coil
resistance
10%
1A SPSTNO 1B SPSTNC
AgSnO2
100Amax/240VAC
23000VA(COS =1) 2300VA(COS =0.4)
400VAC
Max. Switching Current:100A
1m
104
Item 4.12 of IEC 61810-7
Item 4.30 of IEC 61810-7
106
Item 4 .31 of IEC 61810-7
Switching
voltage
VDC
(<80% of
rated
voltage)
Operating
voltage
range
VDC
Pulse
magnitude
ms
Coil
power
consumption
W
Operate
Time
ms
Reset
Time
ms
2 COIL
006-4500
6
28
<4.8
4.9~10
012-4500
12
2 32
<9.6
9.8~20
36
024-4500
24
2 130
<19.2
19.7~40
1 COIL
006-2250
6
012-2250
12
024-2250
24
16
<4.8
4.9~10
64
<9.6
9.8~20
36
260
<19.2
19.7~40
4.5
12
6
2.25
12
6
CAUTION: 1.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously.
Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three
times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to in
be the magnetically neutral position .
2.Switching voltage is for test purpose only and are no to be used as design criteria.
171
NE720
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
Creepage distance
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
1000M min (at 500VDC)
50Hz 2000V surge Voltage 4kV
50Hz 4000V surge Voltage 12kV
8.4mm
Functional 100m/s2;Survival:1000 m/s2 11ms
10~55Hz Double amplitude 1.5mm
5N; 2.5N m
235 2 3 0.5s
-40~85
85% (at 40 )
82g
Item 7 of IEC 61810-5
Item 6 and 8 of IEC 61810-5
Item 6 and 8 of IEC 61810-5
Addenda B of IEC61810-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1and Ud
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Safety approvals
Safety approval
Load
CQC
100A/220VAC
Dimensions
mm /inch
0.028 0.024
0.197 0.197
1.736 0.012
0.571
M0.236
2.362
2.362
Dimensions
0.028 0.024
0.197 0.197
Mounting (Bottom view)
Notes A:NC side
B:NO side
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
3).Relays shall have plus(+) or plus(+) and minus(-) signs placed on
the circuit diagram as shown.
3(-)
4
2(+)
Set Reset
3(-) 4(+) 2(-)
Wiring diagram
Ningbo Huaguan Electronics Corporation LTD.
172