English
Language : 

JQX-54FEA Datasheet, PDF (1/1 Pages) HuaXinAn Electronics CO.,LTD – Can be welded directly onto PCB
JQX- 54FE
30.4 16.0 26.0 26.5
R
R50126381 C US E174722
03001003506
Features
Can be welded directly onto PCB.
Used in household appliances like air conditioning , heater and instruments etc.
Compact high capacity relay for inductive load, rushing current of 70A and steady-state current of 20A.
Ordering Information
JQX-54FE A Z 25 b DC12V
1
2 3 45
6
1 Part number JQX-54FE
2 Contact arrangement A:1A
3 Enclosure Z: Dust cover
4 Contact rating Resistive:25A/250VAC 20A/277VAC
Inductive:20A/250VAC cos =0.4
C 0.9
78
5 Terminal b:PC type NIL:PC type and QC type
6 Coil rated voltage(V) DC:6,9,12,24,48
7 Contact material C:AgCdO NIL:AgSnO2
8 Coil power consumption 0.9:0.9W
Contact Data
Contact Arrangement
Contact Material
Contact Rating
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation Electrical
life
Mechanical
1A SPSTNO
AgSnO2 AgCdO
Resistive: 25A/250VAC, 20A/277VAC Inductive :20A/250VAC,cos =0.4
Motor load:1.5HP 250VAC
6380VA
300VAC
Max. Switching Current:25A rushing current:70A
50m
Item 4.12 of IEC 61810-7
105
Item 4.30 of IEC 61810-7
107
Item 4.31 of IEC 61810-7
Coil Parameter
Dash
numbers
Coil voltage
VDC
Rated Max.
Rated
current
mA
Coil
resistance
10%
Pickup
voltage
VDC(max)
(75%of rated
voltage )
Release
voltage
VDC(min)
(5% of
rated
voltage)
Coil power
consumption
W
Operate Release
Time Time
ms
ms
006-900
6
7.8
150
40
4.5
009-900
9
11.7 100
90
6.7
012-900
12
15.6
75
160
9.0
024-900
24
31.2 37.8
640
18
048-900
48
62.4 18.8
2560
36
0.3
0.5
0.6
0.9
1.2
2.4
20
10
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
105
JQX- 54FE
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
1000M min (at 500VDC)
50Hz 1000V
50Hz 5000V
surge voltage:10kV
Functional:100m/s2 11ms
Survival:1000 m/s2 11ms
10~55Hz
Double amplitude Functional 1.5mm
Double amplitude Survival 2.0mm
10N 8N
235 2
-30~85
20~85%
28g
3 0.5s
Item 7 of IEC 61810-5
Item 6 of IEC 61810-5
Item 6 of IEC 61810-5
Item 8 of IEC 61810-5
IEC68-2-27 Test Ea
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1 and Ua2
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Safety approvals
Safety approval
UL&CUR
Load
25A/250VAC 20A/277VAC
1.5HP250VAC
TU V
25A/250VAC 20A/250VAC COS =0.4
CQC
25A/250VAC
Dimensions
30.4max.
1.197max.
11.8 12
0.465 0.472
0.8
0.031
1.5
0.059
8.4
0.331
1.8
0.071
6.3
0.248
0.8
0.031
2-1.5 1.6
0.059 0.063
1.4
0.055
11.8
0.465
0.8
0.031
12
0.472
3
0.118
1.8
0.3
0.071
0.012
16max.
0.630max.
mm /inch
2- 1.8
0.071
27.6
1.087
1.4
0.055
2- 1.6
0.063
22
0.866
30.4
1.197
5.2
0.205
Mounting (Bottom view)
1.5
0.059
0.8
0.031
1.6
0.063
Dimensions
0.3
0.012
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Wiring diagram (Bottom view)
Ningbo Huaguan Electronics Corporation LTD.
106