JQX-14FC2C Datasheet, PDF (1/2 Pages) HuaXinAn Electronics CO.,LTD – Heavy load, suitable for heavy power reverse
JQX-14FC1 & JQX-14FC2 (4124)JQX-14FC3
JQX-14FC1 & JQX-14FC2 (4124)
JQX-14FC3
29 12.8 26
03001003501
06001015773
R
C
US E174722
R50126370
Features
Heavy load, suitable for heavy power reverse.
Small size, suitable for high-density mounting.
Up to 5000VAC dielectric strength. Between open contacts of JQX-14FC3 3000VAC dielectric strength.
Contact gap of JQX-14FC3 :2¡Á1.5mm=3mm.
Suitable for remote control TV set, copy machine, sales machine and air conditioner etc.
Ordering Information
JQX-14FC1 C S 10 DC12V
1
234
5
1 Part number JQX-14FC1 JQX-14FC2 JQX-14FC3
2 Contact arrangement A:1A 2A:2A C:1C 2C:2C
3 Enclosure S: Sealed type Z: Dust cover
4 Contact current 3A,5A,6A,8A,10A,16A,20A
0.8 3.5
67
5 Coil rated voltage(V) DC:3,5,6,9,12,15,24
AC:6,12,24,48,110,120,220
6 Coil power cunsumption NIL:0.53W 0.8:0.8W 1:1VA
7 Pole-distance 3.5:3.5mm 5:5.0mm
1.2:1.2W
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation life
Electrical
Mechanical
Contact gap
1A SPSTNO 2A DPSTNO 1C SPDT(B-M) 2C DPDT(B-M)
AgCdO AgSnO2
1A:16A/250VAC,30VDC;
1C:10A,16A,20A/250VAC,30VDC;
10A/14VDC(20A Application for 5mm Pole-distance)
2A,2C:5A,8A/220VAC, 30VDC;JQX-14FC3;2A:8A/220VAC;2C:6A/220VAC
Motor load:1HP 250VAC ; 1/2HP 125VAC
Lamp load:TV-5
600W 5000VA
110VDC 380VAC
50m
Max. Switching Current:20A
Item 4.12 of IEC 61810-7
105
107 5 106 (JQX-14FC3)
2 1.5mm=3mm (JQX-14FC3)
Item 4.30 of IEC 61810-7
Item 4.31 of IEC 61810-7
Coil Parameter DC
Dash
numbers
Coil voltage
VDC
003-530
005-530
006-530
009-530
012-530
024-530
048-530
Rated Max
3
3.9
5
6.5
6
7.8
9
11.7
12 15.6
24 31.2
48 62.4
Coil
resistance
10%
C1C2
Pick up
Release
voltage
voltage
VDC(max) VDC(min)
(75%of rated ( 10%of rated
voltage )
voltage )
Coil power
consumption
W
C1C2
17
2.25
0.3
47
3.75
0.5
68
4.50
0.6
153
6.75
0.9
275
9.00
1.2
1100
18.0
2.4
4350
36.0
4.8
0.53
Operate
Time
ms
C1C2
15
Release
Time
ms
C1C2
10
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Ningbo Huaguan Electronics Corporation LTD.