2C800_17 Datasheet, PDF (1/2 Pages) HuaXinAn Electronics CO.,LTD – 2-Electrode Gas Discharge Tubes | |||
|
2-Electrode Gas Discharge Tubes
1ï¼Dimension(mm)
(Ã20.3x4.2mm)
Fast Delivery Time
2:Main Applications
â¢AC Power Lines
â¢Class II (class C) - Requirements
â¢Surge Protection Device/Surge Protector
3:Features
â¢100% Lead-Free(RoHs Compliant )
â¢Non-Radioactive
â¢Low capacitance (â¤4pF)
â¢Fast Response-time,High Insulation Resistance.
4 Electrical Characteristics
DC
Impulse
Spark-over Spark-over
Part
Voltage
Voltage
Number
@100V/s @1.2/50us, 6KV
V
V
2C800
>600
<1500
Nominal AC
discharge current
50 Hz, 0.2sï¼1 shots
A
300
Insulation
Resistance
GΩ
>1
Arc
Voltage
ï¼at 1A)
Capacitance
(1MHz)
V
PF
~30
â¤4
5 Life Test
Item A
15 shots 8/20us
30KA
Item B
10 shot 10/350us
25KA
Item C
15shots 8/20us
30KA
Item A based on IEC61643-11, Item B based on customer's request .For each item new gas
discharge tubes shall be used.
Specifications are subject to change without notice
HUAAN LIMITED
1
www.huaandz.com
sales@huaandz.com
Tel:+86-755-27465585
|
▷ |