Electrical Characteristics, TA = -55°C to +125°C, unless otherwise specified
Parameter
Sym-
bol
Test Conditions
Group
A[13]
Sub-
Group
Limits
Min. Typ.** Max. Units Fig. Note
Current Transfer
Ratio
CTR* IF = 0.5 mA, VO = 0.4 V,
VCC = 4.5 V
1, 2, 3 300 1500
% 3 4, 5
IF = 1.6 mA, VO = 0.4 V,
VCC = 4.5 V
300 1000
IF = 5 mA, VO = 0.4 V,
VCC = 4.5 V
200 500
Logic Low Output
Voltage
VOL IF = 0.5 mA, IOL = 1.5 mA,
VCC = 4.5 V
1, 2, 3
0.11 0.4 V 2 4
IF = 1.6 mA, IOL = 4.8 mA,
VCC = 4.5 V
0.13 0.4
4, 16
IF = 5 mA, IOL = 10 mA,
VCC = 4.5 V
0.16 0.4
4
Logic High Output
Current
IOH* IF = 2 µA, VO = 18 V,
IOHX VCC = 18 V
1, 2, 3
0.001 250 µA
4
250 µA
4, 6
Logic
Low
Single Channel ICCL* IF = 1.6 mA, VCC = 18 V
and LCCC
1, 2, 3
1.0 2 mA
15
Supply Dual Channel
Current
IF1 = IF2 = 1.6 mA,
VCC = 18 V
1.0 4
4
Quad Channel
IF1 =IF2 = IF3 = IF4 = 1.6 mA
VCC = 18 V
1.7 4
Logic Single Channel ICCH* IF = 0 mA,VCC = 18 V
High and LCCC
1, 2, 3
0.001 20 µA
15
Supply Dual Channel
IF1 = IF2 = 0 mA,
40
Current
VCC = 18 V
Quad Channel
IF1 = IF2 = IF3 = IF4 = 0 mA
40
VCC = 18 V
Input Single and
Forward Dual Channel
Voltage
VF* IF = 1.6 mA
1
1.0 1.4 1.7 V 1 4
2
1.7
3
1.8
LCCC
1, 2, 3 1.0 1.4 1.8
Quad Channel
1, 2
1.4 1.7
3
1.8
Input Reverse
Breakdown Voltage
BVR* IR = 10 µA
1, 2, 3 5
V
4
Input-Output
Insulation
II-O* 45% Relative Humidity
1
TA = 25°C, t = 5 s,
Leakage Current
VI-O = 1500 VDC
Capacitance Between
CI-O f = 1 MHz, TA = 25°C
4
Input-Output
1.0 µA
4 pF
7, 12
4, 8
14, 17
*For JEDEC registered parts.
**All typical values are at VCC = 5 V, TA = 25°C.