English
Language : 

HCPL-4562 Datasheet, PDF (7/17 Pages) Agilent(Hewlett-Packard) – High Bandwidth, Analog/Video Optocouplers
VDE 0884 Insulation Related Characteristics (HCNW4562 ONLY)
Description
Symbol Characteristic
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 600 V rms
I-IV
for rated mains voltage ≤ 1000 V rms
I-III
Climatic Classification
55/85/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
VIORM
1414
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
VPR
Partial Discharge < 5 pC
2652
Input to Output Test Voltage, Method a*
VIORM x 1.5 = VPR, Type and sample test,
tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
VPR
VIOTM
2121
8000
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 17, Thermal Derating curve.)
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
TS
IS,INPUT
PS,OUTPUT
RS
150
400
700
≥ 109
Units
V peak
V peak
V peak
V peak
°C
mA
mW
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section (VDE 0884), for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application.
1-391