6
Ethernet evaluation board (Part
# HFBR-0535). This board
allows testing of the fiber-optic
VCSEL transceiver. It includes
the HFBR-53D5 transceiver, test
board, and application
instructions. For single mode
transceiver evaluation the
HFCT-53D5 can be substituted
on this evaluation board. In addi-
tion, a complementary evaluation
board is available for the
HDMP-1636A 1250 MBd
Gigabit Ethernet serializer/
deserializer (SERDES) IC. (Part #
HDMP-163k) Please contact your
local Field Sales representative
for ordering details.
Absolute Maximum Ratings
Parameter
Storage Temperature
Supply Voltage
Data Input Voltage
Transmitter Differential Input Voltage
Output Current
Relative Humidity
Symbol
TS
VCC
VI
VD
ID
RH
Min.
–40
–0.5
–0.5
5
Typ.
Max.
100
7.0
VCC
1.6
50
95
Unit
˚C
V
V
V
mA
%
Reference
1
2
Recommended Operating Conditions
Parameter
Symbol
Ambient Operating Temperature
TA
Case Temperature
TC
Supply Voltage
VCC
Power Supply Rejection
PSR
Transmitter Data Input Voltage – Low
Transmitter Data Input Voltage – High
Transmitter Differential Input Voltage
Data Output Load
Signal Detect Output Load
VIL–VCC
VIH–VCC
VD
RDL
RSDL
Min.
0
4.75
–1.810
–1.165
0.3
50
50
Typ.
50
Max.
70
90
5.25
–1.475
–0.880
1.6
Unit
˚C
˚C
V
mVP–P
V
V
V
Ω
Ω
Reference
3
4
5
5
6
6
Process Compatibility
Parameter
Hand Lead Soldering Temperature/Time
Wave Soldering and Aqueous Wash
Symbol
TSOLD/tSOLD
TSOLD/tSOLD
Min. Typ.
Max. Unit
260/10 ˚C/sec.
260/10 ˚C/sec.
Reference
7
Notes:
1. The transceiver is class 1 eye-safe up to VCC = 7 V.
2. This is the maximum voltage that can be applied across the Differential Transmitter Data Inputs without damaging the input
circuit.
3. Case temperature measurement referenced to the center-top of the internal metal transmitter shield.
4. Tested with a 50 mVP–P sinusoidal signal in the frequency range from 500 Hz to 1500 kHz on the VCC supply with the
recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced.
5. Compatible with 10 K, 10 KH, and 100 K ECL and PECL input signals.
6. The outputs are terminated to VCC –2 V.
7. Aqueous wash pressure < 110 psi.