English
Language : 

HCPL4100 Datasheet, PDF (6/12 Pages) Agilent(Hewlett-Packard) – Optically Coupled 20 mA Current Loop Transmitter
6
Switching Specifications
For 0°C ≤ TA ≤ 70°C, 4.5 V ≤ VCC ≤ 20 V, all typicals at TA = 25°C and VCC = 5 V unless otherwise noted.
See note 12.
Parameter
Propagation Delay Time
to Logic High Output Level
Propagation Delay Time
to Logic Low Output Level
Propagation Delay Time
Skew
Output Rise Time
(10-90%)
Output Fall Time
(90-10%)
Common Mode Transient
Immunity at Logic High
Output Level
Common Mode Transient
Immunity at Logic Low
Output Level
Symbol Min. Typ.
tPLH
0.3
tPHL
0.2
tPLH - tPHL
0.1
Max. Units
1.6 µs
1.0 µs
µs
Test Conditions
CO = 1000 pF,
CL = 15 pF,
IO = 20 mA
CO = 1000 pF,
CL = 15 pF,
IO = 20 mA
IO = 20 mA
Fig. Note
5, 6, 6
7
5, 6, 7
7
tr
16
tf
23
|CMH| 1,000 10,000
|CML| 1,000 10,000
ns IO = 20 mA,
6, 8 8
CO = 1000 pF,
CL = 15 pF
ns IO = 20 mA,
6, 8 9
CO = 1000 pF,
CL = 15 pF
V/µs VI = 2 V,
9, 10 10
TA = 25°C
VCM = 50 V (peak),
VCC = 5 V
IO (min.) = 12 mA
V/µs VI = 0.8 V,
TA = 25°C
9, 10 11
VCM = 50 V (peak),
VCC = 5 V
IO (max.) = 3 mA
Package Characteristics
For 0°C ≤ TA ≤ 70°C, unless otherwise specified. All typicals at TA = 25°C.
Parameter
Symbol Min. Typ. Max. Units Test Conditions
Input-Output Momentary VISO
Withstand Voltage*
Resistance, Input-Output
RI-O
Capacitance, Input-Output CI-O
2500
1012
1
V rms
ohms
pF
RH ≤ 50%, t = 1 min,
TA = 25°C
VI-O = 500 V dc
f = 1 MHz,
VI-O = 0 V dc
Fig. Notes
5, 13
5
5
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable),
your equipment level safety specification, or Agilent Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”