English
Language : 

HCPL-3160 Datasheet, PDF (3/4 Pages) Agilent(Hewlett-Packard) – 2.0 Amp IGBT Gate Drive Optocoupler with Integrated Over-current Protection and Fault Feedback
Preliminary Electrical Specifications (DC)
Over recommended operating conditions (TA = -40 to 100°C) unless otherwise specified.
Parameter
Logic Low
Voltages
Logic High
Voltages
High Level
Output Current
Low Level
Output Current
High Level
Output Voltage
Low Level
Output Voltage
High Level Supply
Current
High Level
Supply Current
High Level
Supply Current
Low Level
Supply Current
Blanking Capacitor
Charging Current
Blanking Capacitor
Discharge Current
UVLO Threshold
UVLO Hysteresis
Desaturation Trip
Voltage
Symbol Min. Typ.*
INPUT
RESET
FAULT
ENABLE
INPUT 2.0
RESET
FAULT
ENABLE
IOH
0.5 1.5
2.0
IOL
0.5 2.0
2.0
VOH VCC2-4 VCC2-3
Max.
0.8
Units
V
V
A
A
A
A
V
Conditions
VO = VCC2 -4 V
VO = VCC2 15 V
VO = VEE + 2.5 V
VO = VEE + 15
IO = -100 mA
VOL
0.1 0.5
V IO = 100 mA
ICC1H
12 mA Vin = 5 V, VCC1 = 5 V
ICC1L
2
mA Vin = 0 V, VCC1 = 5 V
ICC2H
3
7 mA output open
ICC2L
3
7 mA output open
ICHG
0.2 0.32 0.45 mA Vdesat = 0 V
IDSCHG
60
mA Vdesat = 7 V
VUVLO+
13.0 13.4 V
(10.9) (12.5)
VUVLO- 11.2 11.6
V
(8.7) (9.5)
VUVLO+ -
1.4
V
VUVLO-
VDESAT 6.0 7.0 8.0
V
VCC2 = 1.0 ms ramp,
VO > 5 V
VCC2 = 1.0 ms ramp,
VO > 5 V
*All typical values at TA = 25°C and VCC2 - VEE = 30 V, unless otherwise noted.
1) VUVLO+ and VUVLO- are specified as the VCC2 at which VO exceeds 5 V. The approximate output voltage just prior/after the UVLO
transition is given in parenthesis.
1-214