English
Language : 

HCPL-0710 Datasheet, PDF (3/16 Pages) Agilent(Hewlett-Packard) – 40 ns Prop. Delay, SO-8 Optocoupler
Regulatory Information
The HCPL-0710 has been
approved by the following
organizations:
UL
Recognized under UL 1577,
component recognition program,
File E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File CA
88324.
Insulation and Safety Related Specifications
Parameter
Symbol Value Units
Minimum External Air Gap
L(I01) 4.9 mm
(Clearance)
Minimum External Tracking L(I02) 4.8 mm
(Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
0.08 mm
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
200 Volts
IIIa
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Insulation thickness between emitter and
detector; also known as distance through
insulation.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Absolute Maximum Ratings
Parameter
Storage Temperature
Ambient Operating Temperature[1]
Supply Voltages
Input Voltage
Output Voltage
Average Output Current
Lead Solder Temperature
Solder Reflow Temperature Profile
Symbol
Min.
Max.
Units Figure
TS
-55
125
°C
TA
-40
+100
°C
VDD1, VDD2
0
5.5
Volts
VI
-0.5
VDD1 +0.5
Volts
VO
-0.5
VDD2 +0.5
Volts
IO
10
mA
260°C for 10 sec., 1.6 mm below seating plane
See Solder Reflow Temperature Profile Section
Recommended Operating Conditions
Parameter
Symbol
Ambient Operating Temperature
Supply Voltages
Logic High Input Voltage
Logic Low Input Voltage
Input Signal Rise and Fall Times
TA
VDD1, VDD2
VIH
VIL
tr, tf
Min.
0
4.5
0.8 * VDD1
0.0
Max.
+85
5.5
VDD1
0.8
1.0
Units
°C
V
V
V
ms
Figure
1, 2