Electrical Interface
VCC Limits (V)
Operating
Absolute Rating
Supply Ripple
Min.
Max.
4.5
6.0
-0.3
6.0
100 mV peak to peak
Typical Current Draw - ICC (mA)
VCC
Mode
4.5
5.0
6.0
Idle
8
9
12
Scanning
16
18
24
With LED on
25
29
38
FCC Certification
HP’s SmartWand Readers have
received FCC certification for
their standard configuration only.
Any customer purchasing the
product with stripped and tinned
leads or a connector without
adequate shielding has the
responsibility to comply with FCC
regulations. Moreover, if the HP
SmartWand Reader is purchased
without a connector, the product
becomes defined as a sub-
assembly and the FCC Identifica-
tion number no longer applies.
HP assumes no responsibility or
liability for users of the HP
SmartWand Readers without
connectors that fail to comply
with FCC regulations.
This equipment has been tested
and found to comply with the
limits for a Class B digital device,
pursuant to Part 15 of the FCC
Rules. Operation is subject to the
following two conditions: (1) This
device may not cause harmful
interference, and (2) this device
must accept any interference
received, including interference
that may cause undesired
operation.
Model
FCC Identification
HBSW-8XXX FCC ID: B94KDRZ
Series
General Mechanical Specifications
SAPHIRE TIP
LED
23.0 (0.9)
H HEWLETT PACKARD
160 (6.3)
19.0 (0.8)
33
(1.3)
24.9
(0.98)
7.6 (0.3)
15.2 (0.6)
38.1 (1.5)
66 (2.6)
300 (12)
200 (8)
230 (9)
180 (7)
790 (31)
590 (27)
H HEWLETT PACKARD
160 (6.2)
13.3 (0.52) DIA.
24.9
33 (0.98)
(1.3)
7.6 (0.3)
15.2 (0.6)
38.1 (1.5)
66 (2.6)
300 (12)
200 (8)
DIMENSIONS IN MILLIMETERS (INCHES)
23.9 (0.94)
17.6 (0.69)
230 (9)
180 (7)
790 (31)
590 (27)
The CE Mark demonstrates
compliance with EC directives on
EMC.
4-68