English
Language : 

HSMS-280X Datasheet, PDF (2/10 Pages) Agilent(Hewlett-Packard) – Surface Mount RF Schottky Barrier Diodes
2
Pin Connections and Package Marking, SOT-363
1
6
Notes:
1. Package marking provides
2
5
orientation and identification.
2. See “Electrical Specifications” for
3
4
appropriate package marking.
ESD WARNING:
Handling Precautions Should Be Taken
To Avoid Static Discharge.
Absolute Maximum Ratings[1] TC = 25°C
Symbol
Parameter
Unit
SOT-23 / SOT-143
SOT-323 / SOT-363
If
Forward Current (1 µs Pulse)
Amp
1
PIV
Peak Inverse Voltage
V
Same as VBR
Tj
Junction Temperature
°C
150
Tstg
Storage Temperature
°C
-65 to 150
θjc
Thermal Resistance[2]
°C/W
500
1
Same as VBR
150
-65 to 150
150
Notes:
1. Operation in excess of any one of these conditions may result in permanent damage to the device.
2. TC = +25°C, where TC is defined to be the temperature at the package pins where contact is made to the circuit board.
Electrical Specifications TA = 25°C, Single Diode[4]
Part Package
Number Marking Lead
HSMS[5] Code Code Configuration
Minimum
Breakdown
Voltage
VBR (V)
Maximum
Forward
Voltage
VF (mV)
Maximum
Forward
Voltage
VF (V) @
IF (mA)
Maximum
Reverse
Leakage
IR (nA) @
VR (V)
Maximum
Capacitance
CT (pF)
Typical
Dynamic
Resistance
RD (Ω) [6]
2800
2802
A0[3]
A2[3]
0 Single
2 Series
70
410
1.0 15 200 50
2.0
35
2803
2804
2805
A3[3]
A4[3]
A5[3]
3 Common Anode
4 Common Cathode
5 Unconnected Pair
2807
2808
280B
A7[3]
A8[3]
A0[7]
7 Ring Quad[5]
8 Bridge Quad[5]
B Single
280C
280E
280F
A2[7]
A3[7]
A4[7]
C Series
E Common Anode
F Common Cathode
280K
AK[7]
K High Isolation
280L
280M
280N
280P
280R
AL[7]
H[7]
N[7]
AP[7]
O[7]
Unconnected Pair
L Unconnected Trio
M Common Cathode Quad
N Common Anode Quad
P Bridge Quad
R Ring Quad
Test Conditions
IR = 10 µA IF = 1 mA
VF = 0 V
f = 1 MHz
Notes:
1. ∆VF for diodes in pairs and quads in 15 mV maximum at 1 mA.
2. ∆CTO for diodes in pairs and quads is 0.2 pF maximum.
3. Package marking code is in white.
4. Effective Carrier Lifetime (τ) for all these diodes is 100 ps maximum measured with Krakauer method at 5 mA.
5. See section titled “Quad Capacitance.”
6. RD = RS + 5.2 Ω at 25°C and If = 5 mA.
7. Package marking code is laser marked.
IF = 5 mA