Characteristics
Probe
characteristics
Bandwidth (-3 dB)
Rise time (10% - 90%)
Attenuation ratio
Input resistance (when
terminated into 1 MΩ)
Maximum input voltage
Scope compensation
range
Probe ID
Cable length
Safety
Operating Temperature
Storage Temperature
N2862B
N2863B N2889A
N2890A
150 MHz
300 MHz
350MHz (@10:1), 500 MHz
10MHz (@1:1)
2.33 nsec
1.16 nsec
1 nsec (@10:1), 700 psec
35 nsec (@1:1)
10:1
10:1
1:1/10:1 (switch- 10:1
able)
10 MΩ
10 MΩ
10 MΩ (@10:1), 10 MΩ
1 MΩ (@1:1)
300 V RMS (or >400Vpk) CAT
I and CAT II
300 VRMS (or
>400Vpk) CAT I/
II (@10:1), 150
V RMS CAT I/II
(@1:1)
300 V RMS (or
>400Vpk) CAT I
and CAT II
5-30 pF
5-30 pF
5-30 pF (@10:1) 5-30 pF
Yes
1.2 m
Yes
No
Yes
1.2 m
1.3 m
1.3 m
Conformance to IEC-61010-031:2002
0 to 50 ºC, 80% RH
0 to 50 ºC, 80% RH