English
Language : 

AMMP-6530 Datasheet, PDF (1/10 Pages) Agilent(Hewlett-Packard) – 5-30 GHz Image Reject Mixer
Agilent AMMP-6530
5– 30 GHz Image Reject Mixer
Data Sheet
Description
Agilent’s AMMP-6530 is an image
reject mixer that operates from
5 GHz to 30 GHz. The cold
channel FET mixer is designed to
be an easy-to-use component for
any surface mount PCB applica-
tion. It can be used drain pumped
for low conversion loss applica-
tions, or when gate pumped the
mixer can provide high linearity
for SSB up-conversion. An
external 90-degree hybrid is used
to achieve image rejection and a
-1V voltage reference is needed.
Intended applications include
microwave radios, 802.16, VSAT,
and satellite receivers. Since this
one mixer can cover several
bands, the AMMP-6530 can
reduce part inventory. The
integrated mixer eliminates
complex tuning and assembly
processes typically required by
hybrid (discrete-FET or diode)
mixers. The package is fully SMT
compatible with backside ground-
ing and I/O to simplify assembly.
NC
7
Vg
6
NC
5
8
RF
IF1
1
NC
2
IF2
3
gate
4
Top view
Pin Function package base: GND
1
IF1
2
3
IF2
4
LO
5
6
Vg
7
8
RF
Features
• 5x5 mm Surface Mount Package
• Broad Band Performance 5– 30 GHz
• Low Conversion Loss of 8 dB
• High Image Rejection of 15 – 20 dB
• Good 3rd Order Intercept of
+18 dBm
• Single -1V, no current Supply Bias
Applications
• Microwave Radio Systems
• Satellite VSAT, DBS Up/Down Link
• LMDS & Pt-Pt mmW Long Haul
• Broadband Wireless Access
(including 802.16 and 802.20
WiMax)
• WLL and MMDS loops
• Commercial grade military
Absolute Maximum Ratings[1]
Symbol Parameters/Conditions
Units
Min.
Max.
Vg
Gate Supply Voltage
V
0
-3
Pin
CW Input Power
dBm
15
Tch
Operating Channel Temperature
°C
+150
Tstg
Storage Case Temperature
°C
-65
+150
Tmax
Max. Assembly Temp (60 sec max)
°C
+300
Note:
1. Operation in excess of any one of these conditions may result in permanent damage to this device.
Attention: Observe precautions for handling electrostatic sensitive devices.
ESD Machine Model (Class A)
ESD Human Body Model (Class 0)