English
Language : 

HB3891NSIP5D Datasheet, PDF (3/5 Pages) –
Operating temperature rang
Operating temperature rang is the rang of ambient temperatures in which the filter
can be operated continuously. -10℃ ~ +60℃
Storage temperature rang
Storage temperature rang is the rang of ambient temperatures at which the filter can
be stored without damage.
Conditions are as specified elsewhere in these specifications. -40℃ ~ +70℃
Reference temperature
+25℃
2.1 Maximum Rating
DC voltage VDC
12
V
AC voltage Vpp
10
V
2.2 Electrical Characteristics
Source impedance
Zs=50Ω
Load impedance
ZL=2kΩ//3pF
Item
Freq
min
Center frequency
Fo
-
Insertion attenuation
Reference level
38.912MHz
16.7
Pass bandwidth
B3dB
B30dB
-
-
30.01~36.27MHz
38.0
Sidelobe
36.27~37.31MHz
40.61~41.41MHz
36.0
36.0
41.41~50.01MHz
38.0
Temperature coefficient
Between any terminals
Between any terminals
typ
38.912
18.7
1.52
2.62
47.0
44.0
42.0
45.0
-18
TA=25℃
max
-
MHz
20.7
dB
-
MHz
-
MHz
dB
dB
dB
dB
ppm/k
2.3 Environmental Performance Characteristics
Item Test condition
Allowable change of absolute
Level at center frequency(dB)
High temperature test
70℃ 1000H
< 1.0
Low temperature test
-40℃ 1000H
< 1.0
Humidity test
40℃ 90-95% 1000H
< 1.0
Thermal shock
-20℃==25℃==80℃ 20 cycle
< 1.0
30M 10M 30M
Solder temperature test
Sold temp.260℃ for 10 sec.
< 1.0
Soldering
More then 95% of total
2