English
Language : 

HB3624DSIP5D Datasheet, PDF (3/5 Pages) –
Operating temperature rang
Operating temperature rang is the rang of ambient temperatures in which the filter
can be
operated continuously. -10℃ ~ +60℃
Storage temperature rang
Storage temperature rang is the rang of ambient temperatures at which the filter can
be stored without damage.
Conditions are as specified elsewhere in these specifications. -40℃ ~ +70℃
Reference temperature
+25℃
2.1 Maximum Rating
DC voltage VDC
12
V
Between any terminals
AC voltage Vpp
10
V
Between any terminals
2.2 Characteristics of channel 1 (switching input pin 2 connected to ground)
Source impedance
Zs=50Ω
Load impedance
ZL=2kΩ//3pF
TA=25℃
Item
Freq
min
typ
max
Center frequency
Fo
-
36.00
-
MHz
Insertion attenuation
Reference level
36.00MHz
19.0
Pass bandwidth
B3dB
B15dB
-
-
30.75MHz 38.0
40.25MHz 16.0
Relative attenuation 40.75MHz 30.0
41.25MHz 32.0
31.80MHz 10.0
Sidelobe
25.00~30.750MHz
41.50~45.00MHz
32.0
32.0
21.0 23.0
dB
7.7
-
MHz
8.3
-
MHz
48.0
-
dB
28.0
-
dB
39.0
-
dB
41.0
-
dB
17.0
-
dB
39.0
-
dB
40.0
-
dB
Reflected wave signal suppression
1.2 us … 6.0 us after main pulse
(test pulse 250 ns ,
40.0
48.0
dB
carrier frequency 36.00MHz)
Group delay ripple (p-p)
32.20~39.80 MHz
-
60
-
ns
Temperature coefficient
-72
ppm/k
2