HB3622SSIP5D Datasheet, PDF (3/7 Pages) – | |||
|
◁ |
Operating temperature rang
Operating temperature rang is the rang of ambient temperatures in which the filter
can be
operated continuously. -10â ~ +60â
Storage temperature rang
Storage temperature rang is the rang of ambient temperatures at which the filter can
be stored without damage.
Conditions are as specified elsewhere in these specifications. -40â ~ +70â
Reference temperature
+25â
2.1 Maximum Rating
DC voltage VDC
12
V
Between any terminals
AC voltage Vpp
10
V
Between any terminals
2.2 Characteristics of channel 1 (switching input pin 2 connected to pin 3)
Source impedance
Zs=50Ω
Load impedance
ZL=2kΩ//3pF
TA=25â
Item
Freq
min
typ
max
Center frequency
Fo
-
36.17
-
MHz
Insertion attenuation
Reference level
36.17MHz
19.0
B1.5dB
7.4
Pass bandwidth
B3dB
7.7
B10dB
8.6
21.0 23.0
dB
7.7
8.0 MHz
8.0
8.3 MHz
8.9
9.2 MHz
B30dB
8.8
9.4
10.0 MHz
25.00~31.15MHz
33.0
40.0
-
dB
Sidelobe
41.15~42.0MHz
31.0
36.0
-
dB
42.00~45.00MHz
34.0
41.0
-
dB
Reflected wave signal suppression
1.2 us ⦠6.0 us after main pulse
(test pulse 250 ns ,
42.0
50.0
dB
carrier frequency 36.17 MHz)
Group delay ripple (p-p)
32.25~40.05 MHz
-
50
-
ns
Temperature coefficient
-72
ppm/k
2
|
▷ |