English
Language : 

HB3612SSIP5D Datasheet, PDF (3/5 Pages) –
Operating temperature rang
Operating temperature rang is the rang of ambient temperatures in which the filter
can be operated continuously. -10℃ ~ +60℃
Storage temperature rang
Storage temperature rang is the rang of ambient temperatures at which the filter can
be stored without damage.
Conditions are as specified elsewhere in these specifications. -40℃ ~ +70℃
Reference temperature
+25℃
2.1 Maximum Rating
DC voltage VDC
12
V
AC voltage Vpp
10
V
2.2 Electrical Characteristics
Source impedance
Zs=50Ω
Load impedance
ZL=2kΩ//3pF
Item
Freq
min
Center frequency
Fo
-
Insertion attenuation
Reference level
36.13MHz
18.0
Pass bandwidth
B3dB
B30dB
-
-
33.08MHz
-
Relative attenuation
39.17MHz
32.63MHz
-
-
39.63MHz
-
Sidelobe
25.00~31.65MHz
35.0
40.65~45.00MHz
34.0
Reflected wave signal suppression
1.2 us … 6.0 us after main pulse
(test pulse 250 ns ,
42.0
carrier frequency 36.13 MHz)
Feedthrough signal suppression
1.3 us … 1.2 us before main pulse
(test pulse 250 ns ,
45.0
carrier frequency 36.13 MHz)
Group delay ripple (p-p)
32.63 ~ 39.63 Mhz
-
Impedance at 36.13 Mhz
-
Input: Zin = Rin//Cin
-
Output: Zin = Rin//Cin
-
Temperature coefficient of frequency
Between any terminals
Between any terminals
typ
36.125
20.0
6.9
8.5
0.5
0.6
3.6
3.8
46.0
42.0
TA=25℃
max
-
MHz
22.0
dB
-
MHz
-
MHz
-
dB
-
dB
-
dB
-
dB
-
dB
-
dB
52.0
dB
54.0
dB
50
-
ns
-
-
-
3.4//13.3 - kΩ//pF
2.2//4.3 - kΩ//pF
-72
ppm/k
2