English
Language : 

HB3601D Datasheet, PDF (3/5 Pages) –
Operating temperature rang
Operating temperature rang is the rang of ambient temperatures in which the filter
can be
operated continuously. -10℃ ~ +60℃
Storage temperature rang
Storage temperature rang is the rang of ambient temperatures at which the filter can
be stored without damage.
Conditions are as specified elsewhere in these specifications. -40℃ ~ +70℃
Reference temperature
+25℃
2.1 Maximum Rating
DC voltage VDC
12
V
AC voltage Vpp
10
V
2.2 Electrical Characteristics
Source impedance
Zs=50Ω
Load impedance
ZL=2kΩ//3pF
Item
Freq
min
Center frequency
Fo
-
Insertion attenuation
Reference level
36.00MHz
19.0
B1.5dB
-
Pass bandwidth
B3dB
B15dB
-
-
B30dB
-
31.65MHz 7.0
Relative attenuation
40.35MHz
31.30MHz
7.0
22.0
40.70MHz 22.0
Sidelobe
25.00~31.00MHz
41.00~45.00MHz
32.0
30.0
Temperature coefficient
Between any terminals
Between any terminals
typ
36.00
21.0
7.8
8.1
8.9
9.4
10.0
10.0
29.0
29.0
40.0
38.0
-72
TA=25℃
max
-
MHz
23.0
dB
-
MHz
-
MHz
-
MHz
-
MHz
-
dB
-
dB
-
dB
-
dB
-
dB
-
dB
ppm/k
2.3 Environmental Performance Characteristics
Item Test condition
Allowable change of absolute
Level at center frequency(dB)
High temperature test
70℃ 1000H
< 1.0
Low temperature test
-40℃ 1000H
< 1.0
Humidity test
40℃ 90-95% 1000H
< 1.0
Thermal shock
< 1.0
2