English
Language : 

24PC Datasheet, PDF (39/73 Pages) Honeywell Solid State Electronics Center – Commercial Switches and Sensors
Combi-sensor
COMBI-SENSOR
The Combi-sensor is a liquid pressure/temperature sensor that uses
piezoresistive and thermistor sensing technology to measure water
pressure and temperature. It is designed for use in boiler system water
pressure and inflow temperature measurement applications.
Pressure range:
0 bar to 3.0 bar relative
Accuracy:
±2 % over full range
Response time:
<3 s
Operating temperature:
5 °C to 110 °C [41 °F to 203 °F]
Overpressure:
5 bar for 1 hour
Burst pressure:
9 bar for 1 min
Power supply:
5 Vdc ±10 %
Voltage output:
0.5 Vdc to 4.5 Vdc ratiometric to Vs
Maximum current limit: 250 mA (not self-limiting) (for reverse polarity)
NTC (Negative Temperature Coefficient) characteristics:
10 kOhm
at 25 °C ±3 % beta(25/85) = 3998 K ±2 %
Connection:
Lumberg rast 2.5 edge connector ESL code 312-600
DESCRIPTION
Combi-sensor
REFERENCE
FS300-100
39,0
[1.54]
17,0
[0.67]
41,5
[1.66]
39,0 DIA.
[1.54]
www.honeywell.com/sensing
39