MLH016BSB01B Datasheet, PDF (3/4 Pages) Honeywell Solid State Electronics Center – All Metal Pressure Sensors
Table 4. Performance Specifications (At 25 C [77 F] and at rated excitation unless otherwise specified.)
Parameter
Characteristic
Response time
Accuracy1:
2 ms
>100 psi
<100 psi
Total error band2:
Gage:
<300 psig
±0.25% FSS
±0.50% FSS
±3% FSS
>300 psig
Seal gage:
>300 psis
±2% FSS
±2% FSS
Seal gage without L, M, P termination:
100 psis to 299 psis (-40 °C to 85 °C [-40 °F to 185 °F])
±3% FSS
100 psis to 299 psis (>85 °C to 125 °C [>185 °F to 257 °F]) ±10% FSS
>300 psis (-40 °C to 125 °C [-40 °F to 257 °F])
±2% FSS
Seal gage with L, M, P termination:
100 psis to 299 psis (-40 °C to 65 °C [-40 °F to 149 °F])
±10% FSS
100 psis to 299 psis (>65 °C to 125 °C [>149 °F to 257 °F])
>300 psis (-40 °C to 65 °C [-40 °F to 149 °F])
>300 psis (>65 °C to 125 °C [>149 °F to 257 °F])
±15% FSS
±5% FSS
±15% FSS
Notes:
1. Includes pressure non-linearity (BFSL), pressure hysteresis and non-repeatability. Thermal errors are not included.
2. Includes zero error, span error, thermal effect on zero, thermal effect on span, thermal hysteresis, pressure-non-linearity,
pressure hysteresis and non-repeatability.
Figure 2. Operating and Temperature Compensated Area
for All Regulated Output Options
125
124
123
122
121
120
119
118
117
116
6
Operating and Temperature
Compensated Area for
Regulated Output
8 10 12 14 16 18 20 22 24 26 28 30
Supply Voltage (Vdc)
Note:
The dashed line indicates the operating and temperature
compensated area with a 24 V supply.
Figure 3. Operating and Temperature Compensated Area for
4 mA to 20 mA Output
125
120 10 Ohm
250 Ohm
115 Load
Load
110
105
100
95
90
85
80
Operating and Temperature
75
70
Compensated Area for 4 mA
to 20 mA Output
65
60
6 8 10 12 14 16 18 20 22 24 26 28 30
Supply Voltage (Vdc)
Note:
The operating area is extended with a 250 Ohm resistor.
Higher loads extend the operating area. The dashed line
indicates the operating and temperature compensated area
with a 24 V supply using a 250 Ohm load.
Figure 4. Mounting Dimensions (For reference only. mm/(in).)
Pin and Wire Codes (Option B – Packard)
Pin
Voltage
Current
a
+ excitation
+ excitation
b
output
- excitation
c
common
no connection
A variety of pressure ports and electrical
termination connection options are available.
Refer to the “How to Order” on previous page for
possible combinations. Contact your Honeywell
representative for details.
Honeywell Sensing and Control
3