ASDXAVX010NGSA3 Datasheet, PDF (3/6 Pages) Honeywell Solid State Electronics Center – Low Pressure and Ultra-Low Pressure Digital Output,2 Total Error Band, 10 Inches H20 to 100 psi
Figure 1. Nomenclature and Order Guide
Package Selection13 Calibration Selection
Series
ASDX _ _ X _ _ _ _ _ _ _ _
Pressure Port
AV = Axial port on top, vented cover on bottom
Power Supply Voltage
3 = 3.3 Vdc
5 = 5.0 Vdc
Transfer Function Limits14
A = 10% to 90% calibration
B = 5% to 95% calibration
RR = Radial port on top, radial port on bottom
Output Type15
S = SPI
2 = I2C, Address 0x28
3 = I2C, Address 0x38
4 = I2C, Address 0x48
5 = I2C, Address 0x58
6 = I2C, Address 0x68
7 = I2C, Address 0x78
AC = Axial port, sealed cover (commonly used
for absolute)
RV = Radial port, single
Future Option
Pressure Range16, 17, 18
Gage
Differential
-
010NG = 10 in H2O
005ND = ±5 in H2O
010ND = ±10 in H2O
-
015CD = ±15 cm H2O
025CG = 25 cm H2O 025CD = ±25 cm H2O
001PG = 1 psi
005PG = 5 psi
015PG = 15 psi
030PG = 30 psi
100PG = 100 psi
001PD = ±1 psi
005PD = ±5 psi
015PD = ±15 psi
030PD = ±30 psi
-
-
025MG = 25 mbar
050MG = 50 mbar
100MG = 100 mbar
200MG = 200 mbar
500MG = 500 mbar
015MD = ±15 mbar
025MD = ±25 mbar
050MD = ±50 mbar
100MD = ±100 mbar
200MD = ±200 mbar
500MD = ±500 mbar
001BG = 1 bar
002BG = 2 bar
007BG = 7 bar
001BD = ±1 bar
002BD = ±2 bar
-
003KG = 3 kPa
004KG = 4 kPa
005KG = 5 kPa
010KG = 10 kPa
020KG = 20 kPa
050KG = 50 kPa
100KG = 100 kPa
200KG = 200 kPa
700KG = 700 kPa
003KD = ±3 kPa
004KD = ±4 kPa
005KD = ±5 kPa
010KD = ±10 kPa
020KD = ±20 kPa
050KD = ±50 kPa
100KD = ±100 kPa
200KD = ±200 kPa
-
Absolute
-
-
-
-
-
-
015PA = 15 psi
030PA = 30 psi
100PA = 100 psi
-
-
-
-
-
-
001BA = 1 bar
002BA = 2 bar
007BA = 7 bar
-
-
-
-
-
-
100KA = 100 kPa
200KA = 200 kPa
700KA = 700 kPa
Notes:
13. Other package combinations are possible, please contact Honeywell Customer Service.
14. The transfer function limits define the output of the sensor at a given pressure input. By specifying the output signal at the maximum (Pmax.)
and minimum (Pmin.) limits of the pressure range, the complete transfer curve for the sensor is defined. See Figure 2 for a graphical
representation of each calibration. For the 12-bit digital output, Table 6 provides the output of the sensor at significant percentages. These
outputs are valid at the rated input voltage of the sensor.
15. The output type defines which communication protocol the sensor uses to communicate. Available protocols are I2C or half duplex SPI (sensor
acts only as a slave). This communication protocol is not field selectable, and must be defined when ordering the sensor.
16. Custom pressure ranges are available, please contact Honeywell Customer Service.
17. The pressure units (inches H20, cm H20, psi, mbar, bar, kPa) define the units used during calibration and in the application.
18. See Table 5 for an explanation of sensor types.