English
Language : 

SS345PT Datasheet, PDF (2/4 Pages) Honeywell Solid State Electronics Center – Unipolar Hall-Effect Digital Position Sensors With Built-in Pull-up Resistor
Table 1. SS345PT/SS445P Specifications (At 2.7 to 7 Vdc supply, 4 mA load, TA = -40 ºC to 150 ºC [-40 ºF to 302 ºF]
Characteristic
Condition
Minimum
Typical
Maximum
Unit
Supply voltage
-40 °C to 150 °C [-40 °F to 302 °F]
2.7
5.0
7.0
Vdc
Supply current
G < 25 , Vs = 5 V, 25 °C [77°F]
–
-40 °C to 150 °C [-40 °F to 302 °F]
–
5.5
–
–
14
mA
Output current
–
–
–
4.0
mA
Vsat
G > 260
–
–
0.4
Vdc
Output leakage current
G < 25
–
–
10
µA
Output rise time
Output fall time
25 °C [77 °F]
–
–
–
–
1.5
1.5
µs
Thermal resistance:
SS345PT
–
SS445P
–
303
–
°C/W
–
233
–
Operate
-40 °C to 150 °C [-40 °F to 302 °F]
55
180
280
G
Release
-40 °C to 150 °C [-40 °F to 302 °F]
25
105
240
G
Differential
-40 °C to 150 °C [-40 °F to 302 °F]
10
75
140
G
Operating temperature
–
-40 [-40]
–
150 [302]
°C [°F]
Storage temperature
–
-55 [-67]
–
165 [329]
°C [°F]
NOTICE
The magnetic field strength required to cause the switch to change state (operate and
release) will be as specified in the magnetic characteristics. To test the switch against the
specified magnetic characteristics, the switch must be placed in a uniform magnetic field.
Table 2. SS345PT/SS445P Absolute Maximum Ratings1
Characteristic
Minimum
Typical
Maximum
Unit
Supply voltage
-0.5
–
7.0
V
Applied output voltage
-0.5
–
7.0
V
Output current
Magnetic flux
–
–
8.0
mA
–
–
no limit
G
Note 1: Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and
mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the
device necessarily operate at absolute maximum ratings.
Figure 1. SS345PT/SS445P Current Sinking Output Block
Diagram
Figure 2. Typical SS345PT/SS445P Magnetic
Performance vs Temperature
2
www.honeywell.com/sensing