English
Language : 

SPS-A100D-HAMS Datasheet, PDF (2/4 Pages) Honeywell Solid State Electronics Center – SMARY Position Sensor
Transportation
Aerial work lift platform, front end loader and
digger/excavator boom position
Scissor lift position
Refuse truck lift and automatic reach arm position
Mobile crane steering
Timber harvester/processor equipment cutter arm angle
On-board loader weighing system position
Industrial
Telescoping conveyor elevation
Power generation contact angle
Rail-road crossing arms position
Military
Remote weapon systems elevation
Chassis suspension systems position height
Military vehicle door position
Aerospace:
Ground-based solar panels elevation and azimuth
Ground-based satellite dish elevation and azimuth
Medical:
Robotically-assisted surgery equipment position
Patient bed elevation
For more information on these potential applications, please
see the application note “SMART Position Sensor, 100 and
180 Arc Configurations”.
Table 1. Specifications
Parameter
Characteristic
Component
100 Arc
180 Arc
SPS-A100D-HAMS SPS-A100D-VAMS SPS-A180D-HAMS SPS-A180D-VAMS
Sensing range
0 to 100
0 to 180
Resolution
0.06
0.11
Supply voltage
6 Vdc to 24 Vdc
18 Vdc to 40 Vdc
6 Vdc to 24 Vdc
18 Vdc to 40 Vdc
Output
0.5 Vdc to 4.5 Vdc (10% to 90% of 5 Vdc)
Supply current
Linearity
sensor
only
45 mA max.
±0.4% full scale output
Reverse polarity
26.4 Vdc
40 Vdc
26.4 Vdc
40 Vdc
Sensitivity
40 mV/ ±4% FS
22.22 mV/ ±4% FS
Measurement frequency
312 Hz typ.
Termination
4-pin, M12 connector
Operating temperature
sensor
-40 °C to 85 °C [-40 °F to 185 °F]
Storage temperature
Air gap
Sealing
and
magnet
actuator
-40 °C to 150 °C [-40 °F to 302 °F]
7,8 ±2,5 mm [0.307 ±0.098 in]
8,58 ±2,5 mm [0.338 ±0.098 in]
IP67, IP69K
Shock
50 G half sine wave with 11 ms duration
Vibration
20 G from 10 Hz to 2000 Hz
Housing material
thermoplastic
Approvals
CE
Mounting:
screws
M6 or 1/4-20
recommended torque
6 N m to 8 N m [53.1 in lb to 70.8 in lb]
Material
Strength
magnet
actuator
only
neodymium
10,000 Gauss
Notes:
Tolerance applies for full sense range.
Device used to read analog output must have input impedance greater than 1 MOhm.
The output voltage outside of the valid measurement range will be indeterminate.
Percent linearity is the quotient of the measured output deviation from the best fit line at the
measured temperature to the full scale output span.
NOTICE
Ferrous metal within a 100 mm [3.9 in]
radius of the magnet may affect sensor
performance.
2