English
Language : 

DC001NDR5 Datasheet, PDF (2/4 Pages) Honeywell Solid State Electronics Center – Pressure Sensors
Datasheet -- DC001NDR5
http://catalog.sensing.honeywell.com/printfriendly.asp?FAM=pressu...
Compensated
Yes
Output Calibration Yes
Termination
PCB
Port Style
Barbed
Package Style
Honeywell DI-DC
Typical Sensitivity 5 V/in H2O
Full Scale Span
± 2.0 V typ.
Null Offset
3.5 Vdc typ.
Offset Position
Sensitivity
± 10 mV
Total Error
(% Full Scale)
± 2.0 % typ., ± 3.0 % max.
(See Note 1)
Accuracy
± 0.25 %
(% Best
Line)
Fit
Straight
(See
Note
2)
Operating
-25 °C to 85 °C [-13 °F to 185 °F]
Temperature Range
Compensated
Temperature Range
0 °C to 50 °C [32 °F to 122 °F]
Storage
-40 °C to 125 °C [-40 °F to 257 °F]
Temperature Range
Media
Compatibility
P2 port: DRY GASES ONLY: Media must be compatible with
epoxy based adhesive. P1 port: Wetted materials; Media must
be compatible with nylon housing, epoxy adhesive and silicon.
UNSPSC Code
411121
UNSPSC
Commodity
411121 Transducers
Note 1
Percentage of Full Scale includes: zero calibration, temperature
effect on zero and span, nonlinearity, hysteresis, repeatability,
and stability over the compensated temperature range.
Note 2
Percentage of Best Fit Straight Line includes: nonlinearity,
hysteresis, and repeatability
Availability
Global
Series Name
DC Series
DC001NDR5
Pressure Sensors: Measurement Type: Bidirectional Gage, Differential; Signal
Conditioning: Amplified; Pressure Range: ± 1.0 in H2O; Port Style: Barbed
2 of 4