English
Language : 

CSNE151-100 Datasheet, PDF (2/6 Pages) Honeywell Solid State Electronics Center – Current Sensors Line Guide
Current Sensors Line Guide
Common sense. Global
leadership.
Honeywell S&C offers linear
(analog) open loop, digital, or
closed-loop current sensors.
When any of these sensors
detect predetermined signals,
the system then performs the
designated task. For instance,
the digital signal’s logic level
output may sound an alarm,
start a motor, or open a valve.
The linear signal duplicates
the waveform — often ideal for
feedback elements to control
a motor, or regulate machine
function. And Honeywell’s new
closed-loop current sensor
with magnetoresistive (MR)
technology offers amazing
offset drift performance over
a wide temperature range —
with almost no thermal drift, for
enhanced accuracy.
For proven engineering
expertise, component
dependability, and global
support, trust Honeywell S&C.
Digital/Inductive
Current Sensors
Operate current
Sensed current type
Output
Response time
Accuracy
Mounting
Pinout style
Operating temperature
Supply voltage
CSDA Series
0.5 A.t. nom., 3.5 A.t. nom.
ac or dc
voltage
100 µs
better than 0.5 %
PCB mounting pins or screw mount
3-pin PCB or 3-pin AMP connector
-25 °C to 85 °C [-13 °F to 185 °F]
6 Vdc to 16 Vdc
Closed Loop
Current Sensors
CSNX Series
Sensed current range
Sensed current type
Output
±56 A
ac, dc, impulse
current
Coil turns
2000 (50 Ohm coil)
Response time
< 0.2 µs
Accuracy
±0.24 %
Mounting
PCB on 11-pins
Pinout style
unipolar
Operating temperature
-40 °C to 85 °C
[-40 °F to 185 °F]
Supply voltage
4.75 Vdc to 5.25 Vdc
CSNA Series
CSNF Series
±70 A, ±90 A, ±100 A
ac, dc, impulse
current
1000 (90 or 50 Ohm coil)
2000 (160 or 130 Ohm coil)
< 1 µs
±0.5 %
PCB on 3-pins
offset
0 °C to 70 °C
[32 °F to 158 °F]
±13 Vdc, ±15 Vdc
±150 A, ±180 A, ±200 A
ac, dc, impulse
current
1000 (30 Ohm coil)
2000 (100 Ohm coil)
< 0.5 µs
±0.5 %
PCB on 3-pins
center
-40 °C to 85 °C
[-40 °F to 185 °F]
±12 Vdc to ±15 Vdc
2