English
Language : 

13C5000PS5K Datasheet, PDF (2/8 Pages) Honeywell Solid State Electronics Center – Low-cost, Stainless Steel, Isolated Sensors
Pressure Sensors
Low-cost, Stainless Steel, Isolated Sensors
13 mm Series
PRESSURE SENSOR CHARACTERISTICS (all devices)
Environmental specifications
Compensated temperature range
0 °C to 82 °C [32 °F to 180 °F]
Operating temperature range
-40 °C to 125 °C [-40 °F to 257 °F]
Storage temperature range
-40 °C to 125 °C [-40 °F to 257 °F]
Vibration
10 G at 20 Hz to 2000 Hz
Shock
100 G for 11 ms
Life
Insulation resistance
1 million cycles min.
100 mΩ at 50 Vdc
Maximum ratings
Voltage version “K”
Voltage version “L”
Supply voltage VS = +15 Vdc
Supply current I = +2.0 mA
S
PERFORMANCE CHARACTERISTICS – COMPENSATED SERIES (1)
Characteristic
Minimum
Typical
Zero pressure offset
Pressure non-linearity (3)
Pressure hysteresis (3)
-2
0
–
±0.1
–
±0.015
Repeatability
Temp. effect on span (4)
Temp. effect on offset (4)
–
±0.010
–
±0.5
–
±0.5
Thermal hysteresis (0 °C to 82 °C [32 °F to 180 °F])
Long-term stability of offset and span (5)
Response time (6)
Common mode voltage (voltage version “K”) (9)
–
–
–
0.50
±0.1
±0.1
0.1
1.25
Input resistance (current version “L”)
2.0
4.5
Input resistance (voltage version “K”)
8.0
25
Output resistance
3.0
4.5
Maximum
+2
±0.25
±0.030
±0.030
±1.0
±1.0
±0.3
±0.3
–
2.0
8.0
50
6.0
Units
mV
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
%FSS
ms
Vdc
kΩ
kΩ
kΩ
PRESSURE RANGE SPECIFICATIONS – COMPENSATED SERIES
Catalog Listing
Pressure range
Full scale span (2) Proof pressure (7) Burst pressure (8)
13C 0500P (A,S) (1,4,5,6) (K,L)
0 psi to 500 psi
98 mV to 102 mV 1500 psi
2500 psi
13C 1000P (A,S) (1,4,5,6) (K,L)
0 psi to 1000 psi 98 mV to 102 mV 3000 psi
5000 psi
13C 2000P (A,S) (1,4,5,6) (K,L)
0 psi to 2000 psi 98 mV to 102 mV 6000 psi
10,000 psi
13C 3000P (A,S) (1,4,5,6) (K,L)
0 psi to 3000 psi 98 mV to 102 mV 9000 psi
10,000 psi
13C 5000P (A,S) (1,4,5,6) (K,L)
0 psi to 5000 psi 148 mV to 152 mV 10,000 psi
10,000 psi
NOTES
1. Reference conditions (unless otherwise noted): TA = 25 °C [77 °F]; Supply VS = 10 Vdc ±0.01 Vdc or IS = 1.5 mA
±0.0015 mA.
2. Full-scale span (FSS) is the algebraic difference between the output voltage at full-scale pressure and the output at zero
pressure. FSS is ratiometric to supply voltage.
3. Pressure non-linearity is based on best-fit straight line from zero to the full-scale pressure. Pressure hysteresis is the
maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
4. Maximum error band of the offset voltage or span over the compensated temperature range, relative to the 25 °C [77 °F]
reading.
5. Long-term stability over a six-month period.
6. Response time for a 0 psi to FSS pressure step change, 10 % to 90 % rise time.
7. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
8. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer
case.
9. Common mode voltage as measure from output to ground.
2 Honeywell • Sensing and Control