Installation Instructions for the
4AV Series Vane Sensors
ISSUE 2
PK 87605
PERSONAL INJURY
DO NOT USE these products as safety or
emergency stop devices or in any other application
where failure of the product could result in personal
injury.
Failure to comply with these instructions could
result in death or serious injury.
GENERAL INFORMATION
4AV Hall effect vane sensors include a Hall effect
sensor and a magnet in a common package. They
are operated by passing a ferrous vane through the
gap between the magnet and the sensor.
With no vane in the gap, the output is Operated
(conducting). With the vane in the gap, the output is
Released (non-conducting). The vane actuator is
annealed low carbon cold rolled steel, type AISI
1018 or lower in carbon. Minimum recommended
vane dimensions are required to ensure operating
characteristics will be met.
ELECTRICAL CHARACTERISTICS
Catalog
Listing
Termination
Lead
Length
Supply
Voltage
All Listings
Supply
Current
All Listings
4AV15F
4AV16F
4AV17F
4AV18F
4AV19F
4AV20F
4AV20F-T1*
24 AWG Wire
5.50 ± 0.25
24 AWG Wire
7.45 ± 0.25
24 AWG Wire 13.15 ± 0.50
24 AWG Wire 18.15 ± 0.50
24 AWG Wire 22.00 ± 0.50
.015 X .025 PCB
0.140
.025 X .025
Connector
AMP Terminal
Block 103323-4
4.5 VDC
through
26.5 VDC
18.5 mA Max
@ -40 °C
15.25 mA typical
11.75 mA
@25 °C
typical
4AV20F-T2**
.025 X .025 Molex Terminal
Connector Block 22-05-3041
*Will mate with AMP Connector Housing 87499-8, not supplied
**Will mate with Molex Connector Housing 2695/6471, not supplied
Output
Voltage
All listings
0.4 V Max
@125 °C
0.1 typical
0.075 V
@25 °C typical
Output
Sink Current
All listings
40 mA Max
Dual output
sink currents
are summed
to reach total.
VANE DIMENSIONS (mm/in)
Thickness Min.
Window
Min.
Tooth
1,0/0.4
10,2/.40
10,2/.40
1,6/.06
10,2/.40
6,3/.25
Min. Tooth
Depth
9,27/.365
9,27/.365
Sensing and Control