English
Language : 

24PCEFA6G Datasheet, PDF (2/3 Pages) Honeywell Accelerometers – Interactive Catalog Replaces Catalog Pages
Pressure Sensors
Gage and Differential/Unamplified-Noncompensated
24PC Series
Basic Sensors
FEATURES
ɀ Miniature package
ɀ Variety of gage pressure port config-
urations - easily and quickly modified
for your special needs
ɀ Operable after exposure to frozen
conditions
ɀ Ideal for wet/wet differential
applications
ɀ Choice of termination for gage sensors
ɀ 2 mA constant current excitation signif-
icantly reduces sensitivity shift over
temperature *
ɀ Can be used to measure vacuum or
positive pressure
24PC SERIES PERFORMANCE CHARACTERISTICS at 10.0 ±0.01 VDC
Excitation, 25°C
Min.
Typ.
Max.
Units
Excitation
---
10
12
VDC
Null Offset
−30
0
+30
mV
Null Shift, 25° to 0°, 25° to 50°C
---
±2.0
---
mV
Linearity, P2 > P1, BFSL
---
±0.25 ±1.0
% Span
Span Shift, 25° to 0°, 25° to 50°C
---
±5.0*
---
% Span
Repeatability & Hysteresis
---
±0.15 ---
% Span
Response Time
---
---
1.0
msec
Input Resistance
4.0 K
5.0 K
6.0 K
ohms
Output Resistance
4.0 K
5.0 K
6.0 K
ohms
Stability over One Year
---
±0.5
---
% Span
Weight
---
2
---
grams
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Shock
Vibration
Media (P1 & P2)
−40° to +85°C (−40° to +185°F)
−55° to +100°C (−67° to +212°F)
Qualification tested to 150 g
Qualification tested to 0 to 2 kHz, 20 g sine
Limited only to those media which will not attack
polyetherimide, silicon, fluorosilicone, silicone,
EPDM and neoprene seals.
24PC SERIES ORDER GUIDE
Catalog
Listing
24PCE Type
24PCA Type
24PCB Type
24PCC Type
24PCD Type
24PCF Type
24PCG Type
Pressure
Range
psi
0.5
1.0
5.0
15
30
100
250
Min.
24
30
85
165
240
156
145
Span, mV
Typ.
35
45
115
225
330
225
212
Max.
46
60
145
285
420
294
280
Sensitivity
mV/psi
Typ.
70
45
23
15
11
2.25
0.85
Overpressure
psi Max.
20
20
20
45
60
200
500
*Non-compensated pressure sensors, excited by constant current instead of
voltage, exhibit temperature compensation of Span. Application Note #1
briefly discusses current excitation.
Constant current excitation has an additional benefit of temperature mea-
surement. When driven by a constant current source, a silicon pressure
sensor’s terminal voltage will rise with increased temperature. The rise in
voltage not only compensates the Span, but is also an indication of die
temperature.
Constant Current Excitation Schematic
Honeywell ɀ Sensing and Control ɀ 1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ 1-800-737-3360 Canada
11