E1321AA Datasheet, PDF (1/1 Pages) HOKURIKU ELECTRIC INDUSTRY CO.,LTD – Relative Humidity Sensor
䇼Humidity Sensors䇽
Relative Humidity Sensor
Model No. HIS-06-N
+1
7 -0.3
4㫧0.5
Item
Absolute
Rated Voltage
Maximum Rated Wattage
Ratings
Storage Temperature Range
Storage Humidity Range
Operating Operating Temperature Range
Conditions Operating Humidity Range
Electrical Output
Performances Output Accuracy
Hysteresis
Response
䇼Humidity Sensor Modules䇽
Model No. HSU-04A1-N
0.5 Typ.
0.25 Typ.
2.5 Typ.
HIS-06-N
AC 5.5V Max.
1.0mW
-25㷄䌾70㷄
0%RH䌾90%RH
-20㷄䌾60㷄
0%RH䌾90%RH
45.8k㱅(at䋺25㷄/50%RH)
㫧5%RH(at䋺25㷄/50%RH)
㫧1%RH(at䋺30%RH䌾90%RH)
3.5minutes (Typ.) (at䋺30%RH㹤90%RH,90% Reach, 1.2cm/sec.)
Model No. HSU-07A1-N/A2-N
Model No. HSU-07B1-N/B2-N
18㫧0.5
(9)
5
ã±¢4Hole 12Max.
7 Max. 1.6Typ 3.4 Max.
5 (9)
䌈䌓䌕䋭䋰䋴
(3)
(2) 1 2 3 4
0.8Typ.
18㫧0.5
5
ã±¢4Hole 11.6Max.
6 Max. 1.6Typ 4 Max.
5 (9)
䌈䌓䌕䋭䋰䋷
(5.5)
(2)
(2) (12)
(2)
(4) 1 2 3 4 (4)
Model No. HSU-07F1V1-N/F1V2-N
Model No. HSU-07D-N
18㫧0.5
䌈䌓䌕䋭䋰䋷
11.6Max.
6 Max. 1.6Typ 4 Max.
(5.5)
(2)
(2) (12)
(2)
(4) 1 2 3 (4)
18㫧0.5
(9)
5
ã±¢4Hole 11.6Max.
6 Max. 1.6Typ 4 Max.
3
5 (9)
㪟㪪㪬㪄㪇㪎㪝㪈㪭㪈
(3)
(2) 1 2 3 4
17.6㫧0.5
(4Max.)(1.6) (4)
S5䋺Power Supply Terminal
Vo䋺Output Terminal
GND䋺Thermistor,
GND Terminal
THR䋺Thermistor Terminal
Item
HSU-04A1-N
Absolute
Rated Voltage
Maximum Storage Temperature Range
Ratings
Storage Humidity Range
Operating Operating Temperature Range
Conditions Operating Humidity Range 10%RH䌾90%RH
Electrical Output Accuracy
Performances Current Consumption
Hysteresis
Thermistor Characteristics
Response
HSU-07A1-N/A2-N HSU-07B1-N/B2-N HSU-07F1V1-N HSU-07F1V2-N
HSU-07D-N
DC 5.0V (4.75V䌾5.25V)
DC3.3V (3.135V䌾3.465V) DC 5.0V (4.75V䌾5.25V)
-25㷄䌾70㷄
0%RH䌾90%RH
-20㷄䌾60㷄
20%RH䌾90%RH
10%RH䌾90%RH
㫧5%RH at25㷄:40%RH/60%RH
1.3mA Typ.
2mA Typ.
㫧1%RH(at䋺30%RH䌾90%RH)
R25=50k㱅㫧5%, B25/50=4000K㫧200K
R25=1.7k㱅㫧2%, B25/50=3900K㫧195K
3.5 minutes(Typ.) (at䋺30%RH㹤90%RH,90% Reach,1.2cm/sec.)
HOKURIKU