English
Language : 

HVP200 Datasheet, PDF (1/2 Pages) HITRON ELECTRONICS CORPORTION – UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME AND ACTIVE CURRENT SHARING MULTI-OUTPUT 200 WATTS INTERNAL SWITCHING POWER SUPPLIES
H HiTRON
UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME
AND ACTIVE CURRENT SHARING MULTI-OUTPUT 200 WATTS
INTERNAL SWITCHING POWER SUPPLIES HVP200 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
MEET IEC 61000-3-2 HARMONIC CORRECTION
THIRD-WIRE LOADING SHARING
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB.22 CLASS B
+5V STAND-BY GREEN POWER
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: Molex #5273 V-M connector.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 33A @230Vac.
Input Current: 2.25A @115Vac, 1.0 A@230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB.22 Class B.
Hold-up Time: 18mS @115Vac & 230Vac.
Power Fail Signal: Installed.
DC OK Signal: Installed in VO1 & VO2.
Power Factor Correction: Meet Harmonic Correction
per IEC 61000-3-2 PF typ. 0.97-0.99.
Remote Inhibit: Installed. Enable active high.
Over Temperature Protection: Thermostat @ 95°C.
Earth Leakage: Less than 0.75mA.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: Molex #5273 V-M connector.
Output Wattage: Convection 150 watts.
With 30 cfm forced air 200W.
Line Regulation: Typ. 0.1%.
Load Regulation: Main O/P VO1: Typ. ±1.0%.
Aux. O/P VO2: Typ. ±1.0%. (Magnetic Amp).
Aux. O/P VO3,4,5: Typ. ±2-3.0%. (P.R.).
Stand-By Green Power: +5V/50mA available.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Available at VO1 & VO2.
Remote Sense: Installed in VO1 & VO2.
Adjustability: Available at VO1 & VO2.
Load Sharing: Active current sharing circuit at VO1.
Overload Protection (OLP): Fully protected against output
overload and short circuit.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 65-70%.
Operating Temperature: 0 to +50°C under forced air flow
Switching Frequency: Fixed frequency at 70K Hz.
for full load.
Circuit Topology: PWM fixed-frequency forward circuit. Storage Temperature: -20 to +85°C.
Transient Response: Output voltage returns in less than Temperature Coefficient: Typ. ±0.04%/ °C.
3mS following a 25% load change. Cooling: 30 cfm air flow is required to deliver
Safety Standard: UL 60950-1/EN 60950-1 Class I.
the full power 200W.
Power Density: 3.0 Watts / Cubic Inch.
Construction: U-bracket construction format.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
-53-
For the details of safety approval, please consult the factory.