English
Language : 

HVI63 Datasheet, PDF (1/2 Pages) HITRON ELECTRONICS CORPORTION – UNIVERSAL INPUT AC-DC OPEN FRAME SINGLE & TRIPLE OUTPUT 63 WATTS INTERNAL SWITCHING POWER SUPPLIES
H HiTRON
UNIVERSAL INPUT AC-DC OPEN FRAME SINGLE &
TRIPLE OUTPUT 63 WATTS INTERNAL SWITCHING
POWER SUPPLIES HVI63 SERIES
FEATURES:
„ ACCOMMODATE UNIVERSAL AC SOURCES
„ COMPACT 4”x2”x1”PCB FORMAT
„ MEET UNIVERSAL SAFETY STANDARDS
„ EMI MEET CISPR PUB. 22 & FCC CLASS B
„ CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Range typ. 90-264Vac.
Rating 100 to 240Vac.
Input Connector: V-M connector.
Input Frequency: 47-63Hz.
Inrush Current: ≤12.0A rms @ cold start @230Vac.
Input Current: Typ. 0.9A@115Vac, 0.435A@230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class B.
Hold-up Time: Typ. 11.2mS @115Vac, 72.mS @ 230Vac.
Earth Leakage: Less than 0.42mA @230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: V-M connector.
Output Wattage: Typ. 62 watts.
Line Regulation: Typ. 0.1%.
Load Regulation: Main VO1 typ. ±1.0%.
Aux. VO2 typ. ±3-8.0%.
Aux. VO3 typ. ±3.0%.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in at main output VO1(Latch).
Adjustability: Not available.
Overload Protection (OLP):
Fully protected against outputs overload and short circuit.
Typ. OLP set at 105-120% of rating output power.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 80-89.5 %. (Various with output voltage).
Switching Frequency: 130KHz or 70K Hz.
Circuit Topology: Fixed frequency forward circuit for triple
output and 5V/3.3V of single output.
Fixed frequency flyback circuit for high
Operating Temperature: 0 to +50 °C under forced air flow
for full load. Derate by 1.3W/°C
from 40°C to 50°C.
Storage Temperature: -20 to +85°C.
voltage of single output.
Temperature Coefficient: Typ. 0.04%/°C.
Transient Response: Output voltage returns in less than
0.5mS following a 50% load change.
Safety Standard: IEC 60950-1 Class I.
Power Density: 7.7Watts / Cubic Inch.
Cooling: At least 5 cfm direct forward air flow is required to
achieve full rating power.
Construction: 4”x2”x1” PCB format.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
-21-
For the details of safety approval, please consult the factory.