English
Language : 

HVI50 Datasheet, PDF (1/2 Pages) HITRON ELECTRONICS CORPORTION – UNIVERSAL INPUT AC-DC OPEN FRAME SINGLE OUTPUT 50 WATTS INTERNAL SWITCHING POWER SUPPLIES
H HiTRON
UNIVERSAL INPUT AC-DC OPEN FRAME SINGLE OUTPUT
50 WATTS INTERNAL SWITCHING POWER SUPPLIES
HVI50 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
EXTRA LOW PROFILE OPEN FRAME PCB
OR BOX FORMAT
HIGH QUALITY INDUSTRIAL GRADE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Range 90-264Vac.
Rating 100 to 240Vac.
Input Connector: Barrier-Strip Screw Terminal Block or
V-M or Mini PCB Terminal.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 17A@230Vac.
Input Current: Typ. 0.9A @115Vac, 0.45A @230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC B.
Hold-up Time: Typ. 11mS @115Vac, 60mS @230Vac.
Earth Leakage: Less than 0.3mA @ 230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: Barrier-Strip Screw Terminal Block or
V-M or Mini PCB Terminal.
Output Wattage: Typ. 50 Watts.
Line Regulation: Typ. 0.1%.
Load Regulation: Main VO1 typ. ±1.0 %.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in at main VO1 (Latch).
Adjustability: Available at main VO1.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 75-80%.
Operating Temperature: 0 to +50°C.
Switching Frequency: Fixed freq.88K Hz.
Storage Temperature: -20 to +85°C.
Circuit Topology: Fixed freq. flyback circuit.
Temperature Coefficient: Typ. 0.03% /°C.
Transient Response: Output voltage returns in
Cooling: Free air convection cooling.
less than 3mS following
Construction format: L-Bracket or box.
a 25% load change.
Industrial Grade: High quality Industrial Grade.
Safety Standard: UL 60950-1/EN 60950-1 Class I.
Power Density: 2.36Watts /Cubic Inch.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
-17-
For the details of safety approval, please consult the factory.