English
Language : 

HIH100 Datasheet, PDF (1/2 Pages) HITRON ELECTRONICS CORPORTION – AUTO-RANGING INPUT AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING POWER SUPPLIES
H HiTRON
AUTO-RANGING INPUT AC-DC OPEN FRAME SINGLE &
MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING
POWER SUPPLIES HIH100 & HVI100 SERIES
FEATURES:
AUTO-RANGING ACCOMMODATE
AC SOURCES
BOX OR L-BRACKET FORMAT
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Auto-ranging 115(90-132) Vac and
230(180-264) VAC. Transient threshold 150Vac
typical. (Option for dual input selectable)
Input Connector: See Pin assignment.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 20A@115Vac, 40A@230Vac.
Input Current: 2.5A @115Vac, 1.1A @ 230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class B.
Hold-up Time: Typ. 22mS @115Vac, 27mS @230Vac.
Earth leakage: Typ. 0.5mA @230Vac.
Power Fail Signal: Installed.
Logic Inhibit: Optional in HIH100-1X and HVI100-2X
dual output series.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 100 watts.
Output Connector: See pin assignment.
Line Regulation: Typ. 0.1%.
Load Regulation: Main VO1 typ. ±1.0%.
Aux. VO2 typ. ±2.0%. (Magnetic Amp.)
Aux. VO2 typ. ±5.0%. (Stacked-on.)
Aux. VO3/VO4 typ. ±1.5%. (P.R.)
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in at main VO1.
Adjustability: Available at VO1 & VO2.
Remote Sense: Optional in HIH100 & HVI100-2X.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 75%.
Operating Temperature: 0 to +50°C under forced air
Switching Frequency: Fixed-frequency at 100K Hz.
flow for full load.
Circuit Topology: Fixed-frequency forward circuit.
Storage Temperature: -20 to +85°C.
Transient Response: Output voltage returns in less
Temperature Coefficient: Typ. 0.04% /°C.
than 3ms following a 25% load change.
Cooling: Recommended 20cfm cooling fan for full
Safety Standard: UL 60950-1/EN 60950-1 Class I.
rating load.
Power Density: 1.56Watts / Cubic Inch.
Construction: Enclosure box or L-bracket format.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
-27-
For the details of safety approval, please consult the factory.