English
Language : 

HES16B Datasheet, PDF (1/2 Pages) HITRON ELECTRONICS CORPORTION – AC/DC EXTERNAL WALLMOUNT ADAPTER USA OR EUROPEAN INPUT SINGLE OUTPUT 16-18 WATTS SWITCHING POWER SUPPLIES
H HiTRON
AC/DC EXTERNAL WALLMOUNT ADAPTER USA OR
EUROPEAN INPUT SINGLE OUTPUT 16-18 WATTS
SWITCHING POWER SUPPLIES HES16B & HES16C SERIES
FEATURES:
LOW COST WALLMOUNT ADAPTER
DIVERSE AC PLUGS AVAILABLE
MEET DIVERSE SAFETY STANDARDS
EMI MEET EN 55022 OR FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: HES16B typical 90-132Vac,rating 120Vac. Output Voltage: See Ratings Chart.
HES16C typical180-264Vac,rating 230Vac. Output Current: See Ratings Chart.
Input Connector: Wallmount Format.
Output Wattage: 16-18 Watts typical.
HES16B:WM1(U.S.2-blade)/WM2(U.S.3-blade).
HES16C:WM3(Euro-stecker)/WM4(Schuko-stecker)/
WM5(UK)/WM5G(UK)/WM6,6G(Australia).
Input Frequency: 47-63Hz.
Inrush Current: HES16B: 18.0A @ 115Vac typical.
HES16C: 28.0A @ 230Vac typical. (by thermister)
Input Current: HES16B 0.234A @ 115Vac typical.
Output Connector: Optional.
Line Regulation: 0.65% typical.
Load Regulation: ±1.5% typical.
Noise & Ripple: 1.0% typical peak to peak.
OVP: Built-in, By Zener diode clamping.
Adjustability: Factory set.
HES16C 0.133A @ 230Vac typical.
Overload Protection (OLP):
Dielectric Withstand: Meet IEC60950.
Fully protected against output overload and short circuit.
EMI: Meet EN 55022 or FCC Class B.
OLP set at about 120-150% max. load.
Hold-up Time: 27.6mS@115Vac/53.6mS@230Vac typical. Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: 80% typical.
Operating Temperature: 0 to +40°C with no derating.
Switching Frequency: 65-75K Hz.@ full load typical.
Storage Temperature: -20 to +85°C.
Circuit Topology: Free-running flyback circuit.
Temperature Coefficient: 0.04% /°C typical.
Transient Response: Output voltage returns typ. 6mS.
Cooling: Free air convection.
following a 25% load change.
Construction: Impact resistant thermo-plastic
Safety Standard: UL1950/EN60950. Class I or II.
enclosure case.
Power Density: 1.45 Watts / Cubic inch.
Wallmount format.
NOTE:(1) All measurements are at nominal input, full load, and +25°C. unless otherwise specified.
(2) Load regulation is measured at 230Vac or 120Vac in percentage to indicate the change in output voltage as the load varied from half load to full load (±%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft. (2 m) cord AWG#18 wires.
For the details of safety approval, please consult the factory.
Due to requests in market and advances in technology, specifications subject to change without notice.