FEATURES:
ACCOMMODATE UNIVERSAL AC INPUT
DESKTOP IEC320-3P AC RECEPTACLE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET EN 55022/FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Input Connector: IEC320-3P AC receptacle.
Input Frequency: 50-60Hz.
Inrush Current: 32.5A @230Vac by adding thermistor.
Input Current: 1.6A @115Vac &
0.75A @230Vac typical.
Dielectric Withstand: Meet IEC60950.
EMI: Meet EN55022 / FCC Class B.
Hold-up Time: 10mS @115Vac & 56mS @230Vac.
Earth Leakage: 0.45mA @230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 100 Watt typical.
Output Connector & Cord: Option.
Line Regulation: 1% typical.
Load Regulation: ± 1.7% typical.
Noise & Ripple: 1.3% typical peak to peak.
OVP: Built-in, Latched circuit.
Adjustability: Factory set.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
Typical 120-150% max. load.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: 80% typical.
Switching Frequency: Approximate 62K Hz.
Circuit Topology: Fixed frequency Forward circuit.
Transient Response: Output voltage returns in about
1mS following a 25% load change.
Operating Temperature: 0 to +25/35/40°C
without derating. (various with output voltage)
Storage Temperature: -20 to +85°C.
Temperature Coefficient: 0.04%/°C.
Cooling: Internal fan installed.
Construction: Impact resistant thermo- plastic enclosure.
Safety Standard: Meet UL60950/EN60950 Class I.
Power Factor: 0.69 @115Vac./ 0.73@230Vac.
Power Density: 2.44 Watts / Cubic inch.
Desktop Format.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (±%).
(3) The typical cord length is about 1 meter (3.3 ft.), AWG#18 cord for various load conditions.
(4) Due to requests in market and advances in technology, specifications subject to change without notice.
-43-
For the details of safety approval, please consult the factory.