English
Language : 

HES100 Datasheet, PDF (1/2 Pages) HITRON ELECTRONICS CORPORTION – AUTO-RANGING INPUT AC TO DC EXTERNAL DESKTOP ADAPTER MULTIPLE OUTPUT 100-120 WATTS SWITCHING POWER SUPPLIES
H HiTRON
AUTO-RANGING INPUT AC TO DC EXTERNAL DESKTOP ADAPTER
MULTIPLE OUTPUT 100-120 WATTS SWITCHING POWER SUPPLIES
HES100 SERIES
FEATURES:
AUTO-RANGING ACCOMMODATE AC
SOURCES IN THE WORLD
IMPACT RESISTANT THERMO-PLASTIC
LOW-PROFILE ENCLOSURE
MEET UNIVERSAL SAFETY STANDARDS
CONDUCTED EMI MEET EN55022 / FCC
CLASS B, RADIATED EMI MEET CLASS A
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Auto-ranging 115Vac for range 90-132Vac
and 230Vac for range 180-264Vac.
Transient threshold 150Vac typical.
Input Connector: IEC320 3P AC Inlet/Outlet receptacle,
with AC On/Off switch.
Input Frequency: 47-63Hz.
Inrush Current: 20A peak. @115Vac, 40A @230Vac.
Input Current: 2.5A @115Vac, 1.1A @ 230Vac.
Dielectric Withstand: Meet IEC950.
EMI: Conducted EMI meet EN55022 / FCC Class B.
Radiated EMI meet Class A,
Hold-up Time: 22mS @115Vac./ 27mS @230Vac.
Power Fail Signal: Option in all series.
Logic Inhibit: Optional in single & dual output series.
Remote Sensing: Optional for single & dual output series.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ.100-120 Watts.
Output Connector & Cable: Optional.
Cord length typ. 3 ft.(1 meter).
Line Regulation: VO1, VO3 & VO4 ±0.1% typ.
Aux.VO2 ±0.5% typ.
Load Regulation: At strain relief end.
Main O/P VO1 ±1.0% typ.
Aux. O/P VO2 ±2.0% typ. with Mag. Amp. or
±5.0% typ. with Stacked on.
Aux. O/P VO3 & VO4 ±1.5% typ. with PR.
Noise & Ripple: Typ.1.0% peak to peak.
OVP: Main O/P only set @124% ±8% VO1.
Overload Protection: 125-150% of max. power
overrange or short circuit, power foldback
& self-recovering.
GENERAL SPECIFICATION
Efficiency: Typ. 75%.
Operating Temperature: 0 to +40°C.
Switching Frequency: Fixed Frequency at 100K Hz.
Storage Temperature: -20 to +85°C.
Circuit Topology: Fixed Frequency Forward circuit.
Temperature Coefficient: 0.04% /°C.
Transient Response: Output voltage returns in less than Cooling: Built-in 6.5CFM 40mm fan cooling.
3mS following a 25% load change.
Long Term Stability: After 20 minutes warm-up,
Safety Standard: UL1950/EN60950 Class I.
0.1% for 8 hours.
Construction: Desktop enclosure plastic box.
Industrial or Commercial Grade Option:
Power Density: 0.88Watts / Cubic Inch.
" Industrial" higher MTBF, " Commercial" lower cost.
Note: (1) At least 20% of typical main output current is required to maintain stated regulation.
(2) Cord length typical 3 ft. (or 1 meter).
-41-