English
Language : 

HER-48 Datasheet, PDF (1/2 Pages) HITRON ELECTRONICS CORPORTION – AC/DC EXTERNAL REGULATED WALLMOUNT & DESKTOP ADAPTER DIVERSE AC PLUGS SINGLE OUTPUT 6.0-13.0 WATTS LINEAR POWER SUPPLIES
H HiTRON
AC/DC EXTERNAL REGULATED WALLMOUNT & DESKTOP
ADAPTER DIVERSE AC PLUGS SINGLE OUTPUT 6.0-13.0 WATTS
LINEAR POWER SUPPLIES HER-48 SERIES
FEATURES:
COST EFFECTIVE ADAPTORS
WORLDWIDE DIVERSE AC PLUGS
MEET USA OR EUROPEAN STANDARD
LOW NOISE MEET EMI REQUIREMENTS
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Nominal 100/110/120Vac, range -10% to
+6% or 220/230/240Vac, range -10% to
+10%. Custom Vac available.
Input Connector:
Wallmount Format: WM1,2(USA/Japan)/ WM3
(Euro-stecker) / WM4 (Schuko-stecker)/
WM5 (UK)/ WM6, 6G(Australia).
Desktop Format: PT1,2,3,4,5,6,
Input Frequency: 60Hz.for nominal 100/110/120Vac.
50Hz.for nominal 220/230/240Vac.
Input Current: 0.25A max. @100-120Vac/60Hz.
0.15A max. @220-240Vac/50Hz.
Dielectric Withstand: Meet IEC 60950.
EMI: Meet EN 55022 / FCC Class B.
Thermal Protection: Thermal fuse installed in the
input transformer.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 8.5-13Watts typical @120Vac/60Hz input.
6.0-9.6 Watts typical @220-240Vac/50Hz input.
Output Connector: Optional.
Load Regulation: ±5.0% typical at end of 6ft. cord
AWG#20 wires.
(The exactly voltage regulation obtainable
depends upon the output cord & connector
selected and load current.)
Noise & Ripple: Less than 20mV.
Overload Protection: Protected by thermal fuse
buried inside the transformer.
Hold-up Time: Less than 1mS at nominal input and
typical load.
GENERAL SPECIFICATION
Efficiency: Various with output voltage.
Typical 28.0-40.0% @100~120Vac/60Hz input.
Typical 20.0-30.0% @220~240Vac/50Hz input.
Circuit Topology: Line frequency lamination
Operating Temperature: 0 to +25/35/40°C
without derating. (various with output voltage)
Storage Temperature: -20°C to +85°C.
Cooling: Free air convection.
Construction: Impact resistant plastic enclosure case.
steel transformer circuit.
Safety Standard: Meet UL1950/CSA C22.2 NO.950/
Transient Response: Less than 50µS following
a 25% load change.
EN60950 Class I & II.
Wallmount & Desktop Format in EI-48 case.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Due to requests in market and advances in technology, specifications subject to change without notice.
-53-
For the details of safety approval, please consult the factory.