HEPG98 Datasheet, PDF (1/2 Pages) HITRON ELECTRONICS CORPORTION – HARMONIC CORRECTION (PFC) AC/DC EXTERNAL DESKTOP ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 100 WATTS GREEN POWER SWITCHING POWER SUPPLIES
H HiTRON
HARMONIC CORRECTION (PFC) AC/DC EXTERNAL DESKTOP
ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 100 WATTS
GREEN POWER SWITCHING POWER SUPPLIES HEPG98 SERIES
FEATURES:
„ ACCOMMODATE UNIVERSAL AC INPUT
„ DESKTOP IEC320-3PL/2P AC RECEPTACLE
„ GREEN POWER
„ MEET IEC61000-3-2 HARMONIC CORRECTION
„ EMI MEET EN55022/FCC CLASS B
„ MEET UNIVERSAL SAFETY STANDARDS
„ CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Power Factor Correction (PFC) installed.
Input Connector: IEC320-3PL/2P AC receptacle.
Input Frequency: 50/60Hz.
Inrush Current: Typ. 10.6Arms @230Vac 50Hz.
Input Current: 0.97A@115Vac/0.5A@230Vac
Dielectric Withstand: Meet IEC60950-1.
EMI: Meet EN55022/FCC Class B.
Hold-up Time: 15mS @115Vac/ 28mS@230Vac typical.
Green Power: 0.29W @ 132Vac/ 0.45W @264Vac.
Earth Leakage: Less than 0.24mA.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 100 Watts.
Output Connector: Optional.
Line Regulation: 0.2 % typical.
Load Regulation: ± 2.5% typical.
Noise & Ripple: 1% typical peak to peak.
OVP: Built-in. (Latch)
Over Temp. Protection (OTP): Installed.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 110-135% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: 88-90% typical.
Operating Temperature: 0 to +25/35/40°C
Switching Frequency: 25-65 KHz.
without derating. (various with output voltage)
Circuit Topology: Fixed Flyback Circuit.
Storage Temperature: -20 to +85°C.
Transient Response: Output voltage returns in less than
Temperature Coefficient: 0.04%/°C typical.
1mS following a 25% load change.
Safety Standard: Meet UL60950-1/EN60950-1 Class I or II.
Cooling: Free air convection.
Harmonic Current Emission, EN61000-3-2 compliance. Construction: Impact resistant plastic enclosure case.
Power Density: 5.3 Watts/Cubic inch.
Desktop Format.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (±%).
(3) The typical cord length is about 1 meter (3.3 ft.), AWG#18 cord for various load conditions.
(4) Due to requests in market and advances in technology, specifications subject to change without notice
-41-
For the details of safety approval, please consult the factory.