English
Language : 

HEP103 Datasheet, PDF (1/2 Pages) HITRON ELECTRONICS CORPORTION – HARMONIC CORRECTION (PFC) AC/DC EXTERNAL DESKTOP ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 95-103 WATTS SWITCHING POWER SUPPLIES
H HiTRON
HARMONIC CORRECTION (PFC) AC/DC EXTERNAL DESKTOP
ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 95-103 WATTS
SWITCHING POWER SUPPLIES HEP103 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC INPUT
DESKTOP IEC320-3P AC RECEPTACLE
MEETS IEC 61000-3-2 HARMONIC
CORRECTION
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET EN 55022/FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Power Factor Correction (PFC) installed.
Input Connector: IEC320-3P AC receptacle.
Input Frequency: 47-63Hz.
Inrush Current: Cold start 29A @230Vac.
Input Current: 1.1A @115Vac &
0.55A @230Vac typical.
Dielectric Withstand: Meet IEC950.
EMI: Meet EN55022 / FCC Class B.
Hold-up Time: 23mS typical @115Vac & 230Vac.
Over Temp. Protection (OTP): Installed.
Earth Leakage: 0.70mA @230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 95-103 Watts typical.
Output Connector & Cord: Optional.
Line Regulation: 0.1% typical.
Load Regulation: ± 1.5-3.0% typical.
Noise & Ripple: 0.5-1.0% typical peak to peak.
OVP: Built-in, Latched circuit.
Adjustability: Factory set, not available.
Overload Protection:
Typical 110-130% of max. power overrange or
short circuit, power foldback & self-recovering.
GENERAL SPECIFICATION
Efficiency: 80.0% typical.
Operating Temperature: 0 to +40°C.
Switching Frequency: Approximate 165k Hz.
Circuit Topology: Fixed frequency Forward circuit.
Transient Response: Output voltage returns in about
0.1mS following a 25% load change.
Safety Standard: UL1950/EN60950 Class I. Harmonic
Current Emission, EN61000-3-2 compliance.
Power Density: 2.5 Watts / Cubic inch.
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: 0.04%/°C.
Cooling: Internal fan installed.
Construction: Impact resistant thermo- plastic enclosure.
Power Factor: 0.99 @115Vac.
Desktop Format.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (±%).
(3) The typical cord length is about 1 meter (3.3 ft.), AWG#18 cord for various load conditions.
Due to requests in market and advances in technology, specifications subject to change without notice.
-51-
In application