SPECIFICATION
INPUT SPECIFICATION
Input Range: Wide 2:1 Input DC Range 18-36Vdc.
or 36-72Vdc
Input Voltage: Nominal 24Vdc.or 48Vdc.
Input Current: Typical 6.85A full load and 0.06A no-load
@ 24Vdc nominal input.
Typical 2.65A full load and 0.03A no-load
@ 48Vdc nominal input.
Input Fuse: Use external fuse.
Inrush Current: 8A @ 24Vdc/4A @ 48Vdc
Input Filter: Pi-Network for EMI suppression.
Under-Voltage Protection (UVP): Lock-out activated at
17.8 Vdc input @ 24Vdc nominal input.
34-35.5Vdc@ 48Vdc nominal input
Input Reflected Ripple Current: 28.4mA pk-pk @24 Vdc.
Isolation Voltage: 1,500Vdc input-output.
Remote On/Off: TTL/CMOS-Compatible input control.
Positive Logic version for Standard set up:
ON(Enable)=Open(or 2.5-5.0Vdc above-Vin)
OFF(Disable)=Short(or 0-0.8Vdc above-Vin)
Negative Logic version option available by adding a
“N” suffix to the end of Model #.
Remark :Logic input voltage reference to -Vin.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 100-150W typical continuous.
Line Regulation: Various with input & output voltages.
± 0.1% typical.
Load Regulation: Various with output voltages.
Single O/P: ±1.0% typical.
Dual O/P: ±1.0% typical.
Noise & Ripple: Typical 120mV, peak to peak. 1% rms.
OVP: Built-in.
Adjustability: Maybe external trimmed with fixed resistor or
trimpot.
Overload Protection (OLP):
Fully protected against overload and short circuit.
OLP set at typical 130% max. load.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: 83.8-87% typical, various with input.
Switching Frequency: Fixed frequency 330K Hz.
Circuit Topology: Forward Circuit.
Transient Response: Peak deviation <220mV and recovers
within 1mS after 25% load-change.
Safety Standard: IEC60950 Class I.
Case: Aluminum base plate with metal standoffs.
Power Density: 36.0 Watts / Cubic inch.
Operating Temperature: -40 to +100°C (base plate).
Power derating details; please refer to the Derating Chart.
Storage Temperature: -55 to +125 °C.
Temperature Coefficient: ± 0.02%/°C.
Humidity: Up to 95% RH, Non-Condensing.
Cooling: At least 100LFM moving air is recommended for
full load > 0°C in a confined area. Air flow vs. power
Industrial Grade.
derating details please refer to the Derating Chart.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise spec.
(2) Line Regulation measured from High to Low Lines at full load.
(3) Load Regulation measured from Full-Load (F-L) to Half-Load(H-L)at nominal input.
(4) Correct fuse size by calculating the max. DC current drain at low Line input & adding 20-25% for desired fuse size.
Due to requests in market and advances in technology, specifications subject to change without notice.
-37-