HD66113T
At Power Off
Basically, the power-off procedure is the reverse of the power-on procedure.
(1) Set the DISP level to 0.
(2) Lower LCD driver power supply to 0V
(3) Lower VCC and each input signals to 0V
At this time, each V pin input must be at 0V. Display-off function stops when VCC falls to 0V, and
therefore, the LCD driver may output a level other than V2 (lowest level). As a result, a display error may
be caused at power-off or power-on.