N Series●N type Coaxial Connectors
BCable assembly procedure
L0
1 - 0.5
Insulater
Tightener Gasket
Jacket
Outer
conductor
Center
conductor
The cable ends are processed as shown in the drawing. For
the dimensions L1, refer to Table 1, which shows dimansions
arranged L by part number.
(L3) L2±0.1 Surface A
Soldered
Gasket
Clamp
Male or female
contact
(1) Insert clamp from tip of cable and fold outer conductor of
cable back onto clamp. Using a knife, cut off excess outar
conductor left at this time.
(2) Cut off center conductor of cable at L2, from surface A of
cable insulation. For dimensions of L2 and L3, refer to Table
1. L3 is a reference dimension.
(3) Solder cable center conductor and male contact (or female
contact). It is a good idea st this time to solder the contact
preliminarily in advance.
(Note: There must be no gap between the contact and the
cable insulation.)
Nut Gasket
Clamp
Insert cable and parts into shell and fit sharp end of clamp
completely into V-shaped surface of gasket. Tighten tightening
nut sufficiently.
■Remarks
1. The cable dimensions L are based on the MIL and DSP
standards. They may differ somewhat depending on the
type of cable. In such cases, match the dimensions with
the connectors.
2. S o m e c l a m p s a n d g a s k e t s d o e s n o t h a v e n o t
V-shaped, but the assembling procedures are the
same.
Table 1 Dimensions L arranged by part number
Part No.
HRS No.
L1ɹ−00ɹ.5
JUG-536/U(40) 301-0001-4 40
8.6
UG-21D/U(40)
301-0003-0 40
10.0
N-LP-5DW(40) 301-0007-0 40
11.5
UG-23D/U(40)
301-0008-3 40
8.5
UG-22D/U(40)
301-0010-5 40
8.5
N-PJ-58/U(40)
301-0011-8 40
7.4
N-LP-58U(40)
301-0076-3 40
9.2
N-P-3DV(40)
301-0078-9 40
12.3
N-P-5DV(40)
301-0120-3 40
11.1
N-P-5DW(40)
301-0199-3 40
12.0
N-P-5DFB(40)
301-0205-4 40
11.0
N-P-10DFB(40) 301-0206-7 40
11.0
L2±0.1
6
6
4
5
5
3
4
6
6
6
6
6
Unit : mm
L3
1
1
3.5
1
1
3.2
3.6
4.8
1.5
1.5
5
5
8