English
Language : 

MS-136 Datasheet, PDF (1/3 Pages) Hirose Electric – Coaxial Switches
108
Coaxial Switches
MS-136 Series
Inspection Plug MS-136-C (P)
s Features
1.Simplification of Internal Output Checks
The high frequency signal can be simply switched
by coupling or uncoupling.
2.Small, Lightweight Design
Switches are small and lightweight with a height of
3.6 mm, length of 11.5 mm, width of 4.6 mm, and
weight of 0.5 g.
3.Suited to Automatic Mounting
Embossed tape packaging permits automatic
mounting.
MS-136
s Product Specifications
Ratings
Frequency range
Characteristic impedance
Maximum Input Power
DC to 3 GHz
50 ohms
2W
Operating temperature range
Operating relative humidity
-30ç to +85ç
(No freezing)
90% Max.
Item
Standard
1.Contact resistance 50 m ohms max.
2.Insulation resistance 1000 M ohms min.
3.Withstanding voltage No flashover or insulation breakdown
1.3
1.4
4.V.S.W.R.
N•C 1.35 Max.
N•O 1.7 Max.
1.4
1.8
0.3 dB
0.3 dB
5.Insertion loss
N•C 0.4 dB Max.
N•O 0.6 dB Max.
0.5 dB
0.8 dB
20 dB
6.Isolation
16 dB Min.
14 dB
Conditions
10 mA
100 V DC
100 V AC/one minute
DC to 1 GHz
1 to 2 GHz
2 to 3 GHz
DC to 1 GHz
1 to 2 GHz
2 to 3 GHz
DC to 1 GHz
1 to 2 GHz
2 to 3 GHz
7.Vibration
8.Shock
No electrical discontinuity of 1µs or more
Contact resistance: 70 m ohms max.
No damage, cracks, or parts dislocation
Frequency of 10 to 55 Hz, overall amplitude of 1.5 mm
for 2 hours in each of 3 directions
Acceleration of 490 m/s2, sine half-wave waveform,
6 cycles in each of the 3 axis
9.Durability(Insertion/withdrawal) 70 mø or less
5000 cycles
10.Humidity
Contact resistance: 70 m ohms max.
Insulation resistance: 10 M ohms min.
No damage, cracks, or parts dislocation
96 hours at temperature of 40ç and humidity of 90%
to 95%
Contact resistance: 70 m ohms max.
Temperature: -35ç ¡ +5ç to +35ç ¡ +85ç ¡ +5ç to +35ç
11.Temperature cycle Insulation resistance: 1000 M ohms min.
Time: 30 ¡ 15 max. ¡ 30 ¡ 15 max. (Minutes)
No damage, cracks, or parts dislocation
5 cycles
12.Corrosion resistance Contact resistance: 70 m ohms max.
No serious corrosion
Exposed to 5% salt water solution for 48 hours
qThe test method conforms to JIS.
qThe temperature resistance cycle, humidity resistance, and shock resistance tests are verification tests of part deterioration and
looseness, not tests to be conducted at time of switching or when conducting.
s Applications
Portable terminals and mobile wireless equipment.