English
Language : 

ICL8211 Datasheet, PDF (4/14 Pages) Intersil Corporation – Programmable Voltage Detectors
ICL8211, ICL8212
Electrical Specifications V+ = 5V, TA = +25oC Unless Otherwise Specified (Continued)
ICL8211
PARAMETER
SYMBOL
TEST CONDITIONS
MIN TYP MAX
Hysteresis Sat Voltage
VHYS(MAX)
IHYST = -7µA,
measured with
respect to V+
VTH = 1.3V
-
-0.1 -0.2
Max Available
Hysteresis Current
IHYS (MAX)
VTH = 1.3V
-15
-21
-
ICL8212
MIN TYP MAX
-
-0.1 -0.2
-15 -21
-
UNITS
V
µA
Electrical Specifications ICL8211MTY/8212MTY V+ = 5V, TA = -55oC to +125oC
ICL8211
ICL8212
PARAMETER
SYMBOL
TEST CONDITIONS
MIN TYP MAX MIN TYP MAX UNITS
Supply Current
I+
2.8 < V+ < 30
-
-
-
-
-
-
-
Threshold Trip Voltage
VT = 1.3V
VT = 0.8V
VTH
IOUT = 2mA
VOUT = 2V
-
-
100
-
350 350
µA
-
-
350
-
100 100
µA
V+ = 2.8V
0.80
-
1.30 0.80
-
1.30
V
V+ = 30V
0.80
-
1.30 0.80
-
1.30
V
Guaranteed Operating
Supply Voltage Range
VSUPPLY (Note 5)
2.8
-
30 2.8
-
30
V
Threshold Input Current
Output Leakage Current
ITH
IOLK
VTH = 1.15V
VOUT = 30V
Output Saturation
Voltage
Max Available Output
Current
Hysteresis Leakage
Current
Hysteresis Saturation
Voltage
VSAT
IOUT = 3mA
IOH
(Notes 3 & 4)
VOUT = 5V
ILHYS
VHYS(MAX)
V+ = 10V
VHYST = GND
IHYST = -7µA
measured with
respect to V+
-
VTH = 0.8V
-
VTH = 1.3V
-
VTH = 0.8V
-
VTH = 1.3V
-
VTH = 0.8
3
VTH = 1.3V
-
VTH = 0.8V
-
VTH = 1.3V
-
-
400
-
-
-
-
-
20
-
-
0.5
-
-
-
-
-
15
-
-
-
9
-
0.2
-
-
0.3
-
-
400
nA
-
20
µA
-
-
µA
-
-
V
-
0.5
V
-
-
mA
-
-
mA
-
0.2
µA
-
0.3
V
Max Available
Hysteresis Current
IHYS (MAX)
VTH = 1.3V 10
-
-
10
-
-
µA
NOTES:
1. The maximum output current of the ICL8211 is limited by design to 15mA under any operating conditions. The output voltage may be
sustained at any voltage up to +30V as long as the maximum power dissipation of the device is not exceeded.
2. The maximum output current of the ICL8212 is not defined. And systems using the ICL8212 must therefore ensure that the output current
does not exceed 30mA and that the maximum power dissipation of the device is not exceeded.
3. Threshold Trip Voltage is 0.80V(min) to 1.30V(mas). At IOUT = 3mA.
7-164